S5120V2-10P-SI
Item
S5120V2-10P-LI
port
SFP port
2
Rated voltage: 100 VAC to 240 VAC @ 50 or 60 Hz
Input voltage
Max voltage: 90 VAC to 264 VAC @ 47 to 63 Hz
Minimum
7 W
power
consumption
Maximum
power
12 W
consumption
Chassis
leakage
UL60950-1/EN60950-1/IEC60950-1/GB4943
current
compliance
Melting
current of
2 A/250 V
power
module fuse
Cooling
Natural cooling
system
without fan trays
Operating
–5°C to +45°C (23°F to 113°F)
temperature
Operating
5% RH to 95% RH, noncondensing
humidity
Fire
resistance
UL60950-1/EN60950-1/IEC60950-1/GB4943
compliance
Table 16 Technical specifications for S5120V2-SI & S5120V2-LI PoE switch models
S5120V2-10P-
Item
PWR-LI
Dimension
43.6 × 330 × 230
s (H × W ×
mm (1.72 ×
D)
12.99 × 9.06 in)
≤ 3 kg (6.61 lb)
Weight
Console
1 × serial
port
console port
10/100/10
00BASE-T
autosensin
8
g Ethernet
port
S5120V2-20P-LI
4
9 W
19 W
2 A/250 V
Natural cooling
without fan trays
S5120V2-28P-
S5120V2-52P-
PWR-LI
PWR-LI
43.6 × 440 × 260
43.6 × 440 × 400
mm (1.72 ×
mm (1.72 ×
17.32 × 10.24 in)
17.32 × 15.75 in)
≤ 4 kg (8.82 lb)
≤ 6 kg (13.23 lb)
1 × serial
1 × serial
console port
console port
24
48
72
S5120V2-28P-SI
S5120V2-52P- SI
S5120V2-28P-LI
S5120V2-52P- LI
4
4
9 W
18 W
23 W
41 W
2 A/250 V
3.15 A/250 V
Using fixed fan trays
to intake cool air from
the chassis left side
Natural cooling
and exhaust hot air
without fan trays
from the chassis right
side and power
module side
S5120V2-28P-
HPWR-LI
43.6 × 440 × 260
mm (1.72 ×
17.32 × 10.24 in)
≤ 4.5 kg (9.92 lb)
1 × serial
console port
28 (The four
highest-number
ed
10/100/1000BA
SE-T
autosensing
S5120V2-12
TP-HPWR-LI
43.6 × 330 ×
230 mm (1.72
× 12.99 × 9.06
in)
≤ 3 kg (6.61 lb)
1 × serial
console port
10 (The two
highest-numbe
red
10/100/1000B
ASE-T
autosensing

Hide quick links: