Using Z-Wave Devices and Scenes (cont'd)
Door
Set the Door Locks: In the Trigger box, press Add > DOOR > Door Device from the drop-down menu. Select
LOCKED, UNLOCKED or CODE UNLOCKED for the Action. In the Condition box select LOCKED or UNLOCKED.
Next, an action must be programmed.
NOTES:
• Motorized door lock bolts physically lock and unlock when activated, but if the door lock installed is a non-motorized
type, activation allows the door to be manually unlocked without a key. See "Compatible Devices" section later in
this document.
• When using some older Kwikset Smartcode electronic deadbolt door locks (in a Scene that is programmed to trigger
when unlocked) the Scene does not trigger if using a key; enter a user code.
Garage Door
Set the Garage Door: In the Trigger/Condition/Action box, press Add > GARAGE DOOR and select a Garage Door
Device from the drop-down menu or press Select Garage Door Group to activate more than one device. Select
OPENED or CLOSED. The Action Menu option is OPEN or CLOSE. The options for Condition are OPENED and
CLOSED; for Action is OPEN and CLOSE. NOTE: Review the disclaimer in the section "Add Garage Door Module."
Water Valve
Set the Water Valve: In the Trigger/Condition/Action box, press Add > WATER VALVE and select a Water Valve
Device from the drop-down menu or press Select Water Valve Group to activate more than one device. The options for
Trigger/Condition are OPENED and CLOSED; for Action is OPEN and CLOSE.
Zone
Set the Zones: In the Trigger/Condition box, press Add > ZONES and select a zone from the drop-down menu. Select
Restore, Alarm or Fault.
NOTE: Do not use 24-hour silent zone restore/fault in the pre-condition and trigger fields on commercial panels.

Group Setup

A group is a defined collection of the same type of Z-Wave devices that can be used in scenes (such as only light
modules, or only door locks, etc.). When used in a scene, and the scene activates, all devices assigned to that group
activate. Up to 20 groups can be created with up to 5 of the same type devices in each group, such as 5 door locks, etc.
Follow the procedure below to create a Group.
1. Press Group Setup
2. Highlight Group Name field and enter a group name and press GO.
3. Select Group Type (Binary Light, Door Lock, Thermostat, Multilevel Switch, Shades, Water Valve, Garage Door, or
Other) from the drop-down list.
4. Highlight the device(s) from the drop-down list that you want to add to this group and press Save
confirmation message "Z-Wave device group settings saved" is displayed.
NOTES:
• Select Edit
to make changes to existing Groups; use Delete
• The "Water Valve Group" is excluded from the All Switches On/Off command on the "Device Control" page.
> Add
.
31
to delete a Group.
. A