Method For Checking Gas Spring - Komatsu PW118MR-11 Operation & Maintenance Manual

Wheeled excavator
Table of Contents

Advertisement

MAINTENANCE PROCEDURE
6.
Set the lock lever to LOCK position (L).
7.
Stop the engine.
8.
Remove the cab mats and remove the drain plug (2).
9.
Wash the floor with running water without pressure and al-
low the dirt to drain through the hole (1).
10. After washing is completed, dry the floor and the control
pedals if necessary; replace the cap (2) and mats.

METHOD FOR CHECKING GAS SPRING

The gas spring is charged with high-pressure nitrogen gas, so improper handling may cause an explo-
sion resulting in serious personal injury or death. When handling, always observe the following.
Do not disassemble.
Do not bring it near open flame or dispose of it in fire.
Do not perform drilling, welding or flame-cutting.
Do not hit or roll it, or subject it to any impact.
When disposing of it, the gas must be released. Ask your Komatsu distributor to perform this work.
The gas springs are installed inside the left console (1 place)
and at the cab ceiling window (2 places).
In the following cases, ask your Komatsu distributor for inspec-
tion, repair, and replacement.
The lock lever cannot be pulled up lightly or the cab ceiling
window cannot be opened lightly.
The lock lever does not stay at LOCK position.
The cab ceiling window does not stay open.
Oil or gas is found to be leaking from the gas spring.
4-30
k
k
WARNING