4.28 Initial value change list

Displays and sets the parameters changed from the initial value.
Operation
1. Screen at powering ON
The monitor display appears.
2.
Press
to choose the PU operation mode.
3.
Press
to choose the parameter setting
mode.
4.
Turn
until
5.
Pressing
changes to the initial value
change list screen.
6.
Turning
displays the parameter number
changed.
Press
to read the currently set value.
Turn
and press
setting
(refer to step 6 and 7 on page 55)
Turn
to read another parameter.
The display returns to
parameters are displayed.
7.
Pressing
in
the parameter setting mode.
 Turning
 Pressing
REMARKS
 Calibration parameters (C0 (Pr. 900) to C7 (Pr. 905), C42 (Pr. 934) to C45 (Pr. 935)) are not displayed even they are changed from
the initial settings.
 Only simple mode parameter is displayed when simple mode is set (Pr. 160 = 9999 (initial value))
 Only user group is displayed when user group is set (Pr. 160 = "1").
 Pr. 160 is displayed independently of whether the setting value is changed or not.
Parameters referred to 
Pr. 160 User group read selection
C0 (Pr. 900) CA terminal calibration
C2 (Pr. 902) to C7 (Pr. 905) (Frequency setting bias/gain parameter)
C42 (Pr. 934) to C45 (Pr. 935) (PID control)
appears.
to change the
Flicker
after all
status returns to
sets other parameters.
displays the change list again.
Refer to page 185
Refer to page 144
Refer to page 256
Display
PU indication is lit.
PU
EXT NET
PRM indication is lit.
(The parameter number read previously appears.)
Frequency setting complete!!
···
Refer to page 172
Initial value change list