Communication operation and setting
List of calibration parameters
Para
Name
meter
C2
Terminal 2 frequency
(902)
setting bias frequency
C3
Terminal 2 frequency
(902)
setting bias
125
Terminal 2 frequency
(903)
setting gain frequency
C4
Terminal 2 frequency
(903)
setting gain
C5
Terminal 4 frequency
(904)
setting bias frequency
C6
Terminal 4 frequency
(904)
setting bias
126
Terminal 4 frequency
(905)
setting gain frequency
C7
Terminal 4 frequency
(905)
setting gain
[Special monitor selection No.]
Refer to page 136 for details of the monitor description.
Data
Description
H01 Output frequency/speed
H02 Output current
*8
H03 Output voltage
*8
H05 Frequency setting value/speed setting
H06 Running speed
H08 Converter output voltage
H09 Regenerative brake duty
H0A Electronic thermal relay function load factor
H0B Output current peak value
H0C Converter output voltage peak value
H0D Input power
H0E Output power
H0F Input terminal status
H10 Output terminal status
H11 Load meter
H14 Cumulative energization time
H17 Actual operation time
H18 Motor load factor
*1
The setting depends on capacities. (01160 or less/01800 or more)
Input terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, : undetermined value)
*2
b15
Output terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, : undetermined value)
*3
b15
*4
When Pr.37 = "1 to 9998" or Pr. 144 = "2 to 10, 102 to 110," the unit is an integral value (one increment). (Refer to page 134)
*5
Option input terminal 1 monitor details (input terminal status of FR-A7AX when the terminal is ON: 1, when the terminal is OFF: 0) -all terminals
are OFF when an option is not fitted
b15
X15
X14
X13
*6
Option input terminal 2 monitor details (input terminal status of FR-A7AX when the terminal is ON: 1, when the terminal is OFF: 0,
: undetermined value) -all terminals are OFF when an option is not fitted
b15
*7
Option output terminal monitor details (output terminal status of FR-A7AY/A7AR when the terminal is ON: 1, when the terminal is OFF: 0,
: undetermined value) -all terminals are OFF when an option is not fitted
b15
*8
The monitored values are retained even if an inverter fault occurs. Resetting will clear the retained values.
224
Instruction code
Read
Write
Extended
5E
DE
5E
DE
5F
DF
5F
DF
60
E0
60
E0
61
E1
61
E1
Unit
0.01Hz/1
*4 *8
0.01A/0.1A
0.1V
0.01Hz/1
*4
1r/min
0.1V
0.1%
0.1%
0.01A/0.1A
0.1V
0.01kW/0.1kW
0.01kW/0.1kW
*2
*3
0.1%
1h
1h
0.1%
CS
RES
STOP
X12
X11
X10
X9
RA3
Para
Name
meter
C8
Current output bias signal
1
(930)
C9
1
Current output bias current
(930)
C10
Current output gain signal
1
(931)
C11
Current output gain current
1
(931)
C42
1
PID display bias coefficient
(934)
C43
PID display bias analog
1
(934)
value
C44
PID display gain coefficient
1
(935)
C45
PID display gain analog
1
(935)
value
Data
H19 Cumulative power
H32 Power saving effect
*1
H33 Cumulative saving power
H34 PID set point
H35 PID measured value
H36 PID deviation
H3A Option input terminal status 1
H3B Option input terminal status 2
H3C Option output terminal status
*1
H40 PTC thermistor resistance
32-bit cumulative power
*1
H4D
(lower 16-bit)
*1
32-bit cumulative power
H4E
(upper 16-bit)
32-bit cumulative power
H4F
(lower 16-bit)
32-bit cumulative power
H50
(upper 16-bit)
MRS
JOG
RH
RM
ABC2
ABC1
X8
X7
X6
X5
RA2
RA1
Y6
Y5
Instruction code
Read
Write
1E
1E
1F
1F
22
22
23
23
Description
*5
*6
*7
RL
RT
AU
STR
FU
OL
IPF
SU
X4
X3
X2
X1
Y4
Y3
Y2
Y1
Extended
9E
9
9E
9
9F
9
9F
9
A2
9
A2
9
A3
9
A3
9
Unit
1kWh
Variable
Variable
0.1%
0.1%
0.1%
0.01k
1kWh
1kWh
0.01kWh/
0.1kWh
*1
0.01kWh/
0.1kWh
*1
b0
STF
b0
RUN
b0
X0
b0
DY
b0
Y0