Useful functions
(4) List of automatically-set parameters
The following tables show which parameters are changed in each of the automatic parameter settings.
CAUTION
If the automatic setting is performed with Pr. 999 or the parameter setting mode, the listed settings including the changed
parameter settings (changed from the initial setting) will be automatically changed. Before performing the automatic setting,
confirm that changing the listed parameters will not cause any problem.
Normal PID setting
When the PID display increments are not extended
Parameter
759
PID unit selection
774
PU/DU monitor selection 1
775
PU/DU monitor selection 2
776
PU/DU monitor selection 3
934
PID display bias coefficient
935
PID display gain coefficient
* In this setting, the dedicated parameter list is not displayed while FR-PU07-01 is connected. (However, when another setting is made to activate the PID
control, the list may be displayed according to the setting. (Refer to page 315 for the details. )
Extended PID display increment setting
When the PID display increments are extended
Parameter
759
PID unit selection
774
PU/DU monitor selection 1
775
PU/DU monitor selection 2
776
PU/DU monitor selection 3
934
PID display bias coefficient
935
PID display gain coefficient
3-line monitor start setting
* Pr. 934 and Pr. 935 settings affect displays of other parameters. Perform automatic setting of the extended PID display increments first. By doing this, the
dedicated parameter list will be displayed when FR-PU07-01 is connected. In the initial status, the Pr. 999 setting is applied for the display. After the setting, the
Pr. 934 and Pr. 935 settings are applied.
The 3-line monitor is displayed first after the automatic setting while a parameter unit (FR-PU07(-01)) is connected.
GOT initial setting (PU connector) (Pr. 999 = "10")
Parameter
79
Operation mode selection
118
PU communication speed
119
PU communication stop bit length
120
PU communication parity check
121
Number of PU communication retries
122
PU communication check time interval
123
PU communication waiting time setting
124
PU communication CR/LF selection
340
Communication startup mode selection
REMARKS
Always perform an inverter reset after the initial setting.
308
Name
Name
Name
Initial
Automatically set to
value
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
Initial
Automatically set to
value
9999
4
9999
52
9999
53
9999
54
9999
0
9999
100
The 3-line monitor is displayed
9999
first.
Initial
Automatically set to
value
0
1
192
192
1
10
2
1
1
9999
9999
9999
9999
0ms
1
1
0
0
Refer to page
316
318
318
318
268
268
Refer to page
316
318
318
318
268
268
315
Refer to page
190
209
209
209
209
209
209
209
198