Function Parameters
753
Second PID action selection
Second PID control automatic
754
switchover frequency
755
Second PID action set point
756
Second PID proportional band
757
Second PID integral time
758
Second PID differential time
759
PID unit selection
760
Pre-charge fault selection
761
Pre-charge ending level
762
Pre-charge ending time
763
Pre-charge upper detection level
764
Pre-charge time limit
765
Second pre-charge fault selection
766
Second pre-charge ending level
767
Second pre-charge ending time
Second pre-charge upper detection
768
level
769
Second pre-charge time limit
774
PU/DU monitor selection 1
775
PU/DU monitor selection 2
776
PU/DU monitor selection 3
777
4mA input fault operation frequency
778
Current input check filter
Operation frequency during
779
communication error
Pulse increment setting for output
799
power
826
to
Parameter 11 to 50 for user
865
867
AM output filter
869
Current output filter
870
Speed detection hysteresis
872
Input phase loss protection selection
Regeneration avoidance operation
882
selection
Regeneration avoidance operation
883
level
Regeneration avoidance at
884
deceleration detection sensitivity
Regeneration avoidance
885
compensation frequency limit value
886
Regeneration avoidance voltage gain
Name
10, 11, 20, 21, 40, 41,
50, 51, 60, 61, 70, 71,
80, 81, 90, 91, 100, 101,
110, 111, 120, 121, 140,
141, 9999
0 to 400Hz, 9999
0 to 100%, 9999
0.1 to 1000%, 9999
0.1 to 3600s, 9999
0.01 to 10.00s, 9999
0 to 43, 9999
0, 1
0 to 100%, 9999
0 to 3600s, 9999
0 to 100%, 9999
0 to 3600s, 9999
0, 1
0 to 100%, 9999
0 to 3600s, 9999
0 to 100%, 9999
0 to 3600s, 9999
1 to 3, 5, 6, 8 to 14, 17,
20, 23 to 25, 40 to 42,
50 to 57, 64, 67, 81 to
86, 100, 9999
0 to 400Hz, 9999
0 to 10s
0 to 400Hz, 9999
0.1kWh, 1kWh, 10kWh,
100kWh, 1000kWh
0 to 65535
0 to 5s
0 to 5s
0 to 5Hz
0, 1
0, 1, 2
300 to 800V
0 to 5
0 to 30Hz, 9999
0 to 200%
Minimum
Setting Range
Setting
Increments
1
0.01Hz
0.01%
0.1%
0.1s
0.01s
1
1
0.1%
0.1s
0.1%
0.1s
1
0.1%
0.1s
0.1%
0.1s
1
0.01Hz
0.01s
0.01Hz
0.1
1
0.01s
0.01s
0.01Hz
1
1
0.1V
1
0.01Hz
0.1%
Parameter list
Refer
Initial
Customer
to
Value
Setting
Page
9999
275
9999
275
9999
275
100%
275
1s
275
9999
275
9999
316
0
270
9999
270
9999
270
9999
270
9999
270
270,
0
275
270,
9999
275
270,
9999
275
270,
9999
275
270,
9999
275
318
318
9999
318
9999
177
0
177
9999
211
1kWh
133
0
255
0.01s
142
0.02s
142
0Hz
128
0
157
0
294
760V/
294
785VDC
0
294
6Hz
294
100%
294
65
4