Common specifications
Operation
Operating
panel (FR-
status
DU07)
Parameter
unit (FR-
Fault definition
PU07)
Interactive
guidance
Protective
function
Protective/
warning function
Warning
function
LD
Surrounding
air
SLD
temperature
(initial setting)
Ambient humidity
Storage temperature
*3
Atmosphere
Altitude, vibration
*1
Can be displayed only on the operation panel (FR-DU07).
*2
This operation guide is only available with option parameter unit (FR-PU07).
*3
Temperature applicable for a short period in transit, etc.
*4
Only the 01800 or more functions.
2
*5
2.9m/s
or less for the 04320 or more.
*6
This protective function does not function in the initial status.
368
The following operating status can be displayed: output frequency, motor current (steady or
peak value), output voltage, alarm indication, frequency setting, running speed, converter
output voltage (steady or peak value), electronic thermal relay function load factor, input power,
output power, load meter, cumulative energization time, actual operation time, motor load
factor, cumulative power, power saving effect, cumulative saving power, regenerative brake
duty
,PID set point, PID measured value, PID deviation value, inverter I/O terminal monitor,
*4
input terminal option monitor
terminal assignment status
*2
Fault definition is displayed when a fault occurs. Past 8 fault definitions (output voltage/current/
frequency/cumulative energization time right before the fault occurs) are stored.
Function (help) for operation guide
Overcurrent during acceleration, overcurrent during constant speed, overcurrent during
deceleration, overvoltage during acceleration, overvoltage during constant speed, overvoltage
during deceleration, inverter protection thermal operation, motor protection thermal operation,
heatsink overheat, instantaneous power failure occurrence, undervoltage, input phase loss
motor overload, output side earth (ground) fault overcurrent, output phase loss, external thermal
relay operation
, PTC thermistor operation
*6
parameter error, PU disconnection, retry count excess
supply short circuit, 24VDC power output short circuit, output current detection value excess
inrush current limit circuit fault, communication fault (inverter), analog input fault, PID signal fault
, internal circuit fault (15V power supply), brake transistor alarm detection
*6
and 4mA input fault
*6
Fan alarm, overcurrent stall prevention, overvoltage stall prevention, regenerative brake
prealarm
, electronic thermal relay function prealarm, PU stop, maintenance timer alarm
*6
parameter write error, copy operation error, operation panel lock, parameter copy, and password
locked
-10°C to +50°C (non-freezing)
-10°C to +40°C (non-freezing)
90%RH or less (non-condensing)
-20°C to +65°C
Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt etc.)
Maximum 1000m above sea level for standard operation. After that derate by 3% for every
extra 500m up to 2500m (91%).
2
5.9m/s
or less
at 10 to 55Hz (directions of X, Y, Z axes)
*5
, output terminal option monitor
*1
*2
, option fault, communication option fault,
*6
, CPU fault, RS-485 terminal power
*6
, option fitting status monitor
*1
, Pre-charge fault
*4
*1*6
,
*2
,
*6
,
*6
,
*6
,