Parameter list
Function Parameters
888
Free parameter 1
889
Free parameter 2
Cumulative power monitor digit
891
shifted times
892
Load factor
Energy saving monitor reference
893
(motor capacity)
Control selection during commercial
894
power-supply operation
895
Power saving rate reference value
896
Power unit cost
897
Power saving monitor average time
Power saving cumulative monitor
898
clear
899
Operation time rate (estimated value)
C0
CA terminal calibration
(900)
*5
C1
AM terminal calibration
(901)
*5
C2
Terminal 2 frequency setting bias
(902)
frequency
*5
C3
Terminal 2 frequency setting bias
(902)
*5
125
Terminal 2 frequency setting gain
(903)
frequency
*5
C4
Terminal 2 frequency setting gain
(903)
*5
C5
Terminal 4 frequency setting bias
(904)
frequency
*5
C6
Terminal 4 frequency setting bias
(904)
*5
126
Terminal 4 frequency setting gain
(905)
frequency
*5
C7
Terminal 4 frequency setting gain
(905)
*5
C8
Current output bias signal
(930)
*5
C9
Current output bias current
(930)
*5
C10
Current output gain signal
(931)
*5
C11
Current output gain current
(931)
*5
 C42
PID display bias coefficient
(934)
*5
 C43
PID display bias analog value
(934)
*5
 C44
PID display gain coefficient
(935)
*5
 C45
PID display gain analog value
(935)
*5
Terminal 10 calibration for PTC
986
thermistor
66
Name
0 to 9999
0 to 9999
0 to 4, 9999
30 to 150%
0.1 to 55kW/
0 to 3600kW
0, 1, 2, 3
0, 1, 9999
0 to 500, 9999
0, 1 to 1000h, 9999
0, 1, 10, 9999
0 to 100%, 9999
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 500.00, 9999
0 to 300.0%
0 to 500.00, 9999
0 to 300.0%
4 to 6V, 8888, 9999
Minimum
Setting Range
Setting
Increments
0.1%
0.01/0.1kW
*2
*2
0.01
1h
0.1%
0.01Hz
0.1%
0.01Hz
0.1%
0.01Hz
0.1%
0.01Hz
0.1%
0.1%
0.1%
0.1%
0.1%
0.01
0.1%
0.01
0.1%
0.01V
Refer
Initial
to
Value
Page
1
9999
303
1
9999
303
1
9999
159
100%
159
SLD/LD value
of Applied
159
motor Capacity
1
0
159
1
9999
159
9999
159
9999
159
1
9999
159
9999
159
144
144
0Hz
172
0%
172
50Hz
172
100%
172
0Hz
172
20%
172
50Hz
172
100%
172
0%
144
0%
144
100%
144
100%
144
9999
256
20%
256
9999
256
100%
256
5.00V
100
Customer
Setting