Sensor
From original set sensor turn-on until feed roller starts: 1 second
System Settings - General Features - Original Feed Delay 1
Pause at the registration sensor: 1 second
System Settings - General Features - Original Feed Delay 2
Slide 137
There are two delays to allow the user to correct for skew and other feeding
problems before the scan begins.
They are controlled with user tools as shown on the slide.
The machine feeds at 105 mm/s as far as the registration roller.
From that point, the feed speed depends on the reproduction ratio.