10. Install the PCI riser-card assemblies and all adapters, as described in
11. Install the cover, as described in "Installing the cover" on page 84.
12. Push the power supplies back into the server.
13. Slide the file module into the rack.
14. Reconnect the external cables; then, reconnect the power cords and turn on
15. When you replace the system board, update the server firmware, as described
16. From the active management file module terminal application, issue the
17. From the active management file module terminal application, use the
152
Storwize V7000 Unified: Problem Determination Guide Version
4. Rotate the system board release latch toward the rear of the server until the
latch clicks into place.
5. Replace the fans, as described in "Installing a hot-swap fan" on page 134.
6. Install each microprocessor with its matching heat sink, as described in
"Installing a microprocessor and heat sink" on page 142.
This procedure describes how to remove the old thermal grease and apply a
new coat of grease.
7. Install the DIMMs, as described in "Installing a memory module" on page
130.
8. Install the air baffles, as described in "Installing the DIMM air baffle" on page
94 and "Removing the microprocessor 2 air baffle" on page 90.
9. Install the SAS riser-card and controller assembly, as described in "Installing
the SAS riser card and controller assembly" on page 113.
"Installing a PCI riser-card assembly" on page 100.
the peripheral devices and the file module.
Note: You must wait approximately 2.5 minutes after you connect the power
cord of the file module to an electrical outlet before the power-control button
becomes active.
in "Restoring System x firmware (BIOS) settings" on page 258.
following Advanced Settings Utility (ASU) commands to reset the serial
number and the product name of the new system board:
asu set SYSTEM_PROD_DATA.SysInfoSerialNum KQ3497D --host int002st001imm
asu set SYSTEM_PROD_DATA.SysInfoProdName 7947PCV --host int002st001imm
Replace KQ3497D with the serial number of the file module.
Replace int002st001 with the host name of the file module with the new
motherboard.
Replace 7947PCV with the system type of the file module.
Advanced Settings Utility (ASU) to verify the settings for the PCI slots in the
interface file module.
For example, when replacing the system board on the int002st001 interface file
module, query the PCI slot settings:
# asu show all --kcs | grep uEFI.PCIeGenSelection
uEFI.PCIeGenSelection.1=Gen2
uEFI.PCIeGenSelection.10=Gen2
uEFI.PCIeGenSelection.11=Gen2
uEFI.PCIeGenSelection.12=Gen2
uEFI.PCIeGenSelection.13=Gen2
uEFI.PCIeGenSelection.14=Gen2
uEFI.PCIeGenSelection.15=Gen2
uEFI.PCIeGenSelection.16=Gen2
uEFI.PCIeGenSelection.2=Gen2
uEFI.PCIeGenSelection.3=Gen2
uEFI.PCIeGenSelection.4=Gen2
uEFI.PCIeGenSelection.5=Gen2