Note: Before running a procedure, refer to "Removing a file module to perform a
maintenance action" on page 51.
To install the microprocessor air baffle, complete the following steps.
1. To help you work safely with Storwize V7000 Unified file modules, read the
2. Align the tab on the left side of the microprocessor 2 air baffle with the slot in
3. Align the pin on the bottom of the microprocessor air baffle with the hole on
4. Lower the microprocessor 2 air baffle into the file module.
5. Install PCI riser-card assembly 2, if necessary.
6. Install the cover, as described in "Installing the cover" on page 84.
7. Slide the file module into the rack.
8. Reconnect the external cables; then, reconnect the power cords and turn on the
92
Storwize V7000 Unified: Problem Determination Guide Version
safety information in "Safety" on page xi, "Safety statements" on page xiii, and
"Installation guidelines" on page 54.
the right side of the power-supply cage.
the system board retention bracket.
Attention: For proper cooling and airflow, replace all air baffles before you
turn on the file module. Operating the file module with any air baffle removed
might damage file module components.
peripheral devices and the file module.