Removing The Sas Riser-Card And Controller Assembly - IBM Storwize V7000 Unified Series Problem Determination Manual

Hide thumbs Also See for Storwize V7000 Unified Series:
Table of Contents

Advertisement

To remove and store the full-length-adapter bracket, complete the following
procedure.
1. Press the bracket tab 3 and slide the bracket to the left until the bracket falls
free of the riser-card assembly.
2. Align the bracket with the storage location on the riser-card assembly as
shown.
3. Place the two hooks 1 in the two openings 2 in the storage location on the
riser-card assembly.
4. Press the bracket tab 3 and slide the bracket toward the expansion-lot-
opening end of the assembly until the bracket clicks into place.

Removing the SAS riser-card and controller assembly

The following procedure is for a Tier 1 customer replaceable unit (CRU).
Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at
your request, you will be charged for the installation. Service agreements can be
purchased so that you can ask IBM to replace these units.
Note: Before running a procedure, refer to "Removing a file module to perform a
maintenance action" on page 51.
To remove the SAS riser-card and controller assembly from the server, complete the
following procedure.
1. To help you work safely with Storwize V7000 Unified file modules, read the
safety information in "Safety" on page xi, "Safety statements" on page xiii, and
"Installation guidelines" on page 54.
2. To remove the SAS riser-card and controller assembly for a 16-drive-capable
server model, complete the following steps.
Figure 19 on page 112 shows the SAS riser card in the 16-drive-capable server
model.
111
Chapter 4. File module