Cable Lengths - Siemens SCALANCE X-300 Series Operating Instructions Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-300 Series:
Table of Contents

Advertisement

Technical specifications
8.10 SFP technical specifications
8.10.3

Cable lengths

Table 8-116 Permitted cable lengths (fiber-optic) Fast Ethernet
Device:
transceiver
SFP991-1
SFP991-1LD
SFP991-1LH+
Table 8-117 Permitted cable lengths (fiber-optic) gigabit
Device:
transceiver
SFP992-1
SFP992-1+
SFP992-1LD
SFP992-1LH
216
(Variant)
(1 x 100 Mbps, LC port opti‐
cal, multimode glass, up to
max. 3 km)
(1 x 100 Mbps, LC port opti‐
cal, single mode glass, up to
max. 26 km)
(1 x 100 Mbps, LC port opti‐
cal, single mode glass, up to
max. 70km)
(Variant)
(1 x 1000 Mbps, LC port opti‐
cal, multimode glass, up to
max. 750m)
(1x 1000 Mbps, LC port opti‐
cal, multimode glass, up to
max. 2 km)
(1 x 1000 Mbps, LC port opti‐
cal, single mode glass, up to
max. 10km)
(1 x 1000 Mbps, LC port opti‐
cal, single mode glass, up to
max. 40km)
Fiber
FO cable lengths
50/125 µm multi‐
0-3 km
mode fiber
(1 dB/km at 1300 nm;
1200 MHz*km;
maximum insertion loss 0.5 dB;
9 dB max. permitted FO cable attenuation at 3 dB link
power margin)
9/125 µm single
0-26 km
mode fiber
(0.5 dB/km at 1310 nm;
maximum insertion loss 0.5 dB;
14 dB max. permitted FO cable attenuation at 2 dB
link power margin)
9/125 µm single
*) -70 km
mode fiber
(0.28 dB/km at 1550 nm;
maximum insertion loss 0.5 dB,
26 dB max. permitted FO cable attenuation at 2 dB
link power margin,
*) minimum cable attenuation 3 dB)
Fiber
FO cable lengths
62.5/125 µm multi‐
0-350 m
mode fiber
(3.1 dB/km at 850 nm;
1200 MHz*km;
maximum insertion loss 0.5 dB;
4.5 dB max. permitted FO cable attenuation at 3 dB
link power margin)
50/125 µm multi‐
0-750 m
mode fiber
(2.5 dB/km at 850 nm;
1200 MHz*km;
maximum insertion loss 0.5 dB;
4.5 dB max. permitted FO cable attenuation at 3 dB
link power margin)
62.5/125 µm multi‐
0-1 km
mode fiber
50/125 µm multi‐
0-2 km
mode fiber
9/125 µm single
0 -10 km
mode fiber
(0.5 dB/km at 1310 nm;
maximum insertion loss 0.5 dB;
6 dB max. permitted FO cable attenuation at 3 dB link
power margin)
9/125 µm single
*) -40 km
mode fiber
(0.4 dB/km at 1550 nm;
maximum insertion loss 0.5 dB,
18 dB max. permitted FO cable attenuation at 2 dB
link power margin,
*) minimum cable attenuation 3 dB)
Operating Instructions, 11/2019, A5E01113043-24
SCALANCE X-300

Advertisement

Table of Contents
loading

Table of Contents