Certifications and approvals
11.3 Product group XR-300M
The products meet the requirements of the following standards:
● IEC 60079-15 : 2010 (Explosive atmospheres - Part 15: Equipment protection by type of
protection "n"
● IEC 60079-0 : 2011 (Explosive atmospheres - Part 0: Equipment - General requirements)
Note
Only variants with 24 VDC power supply meet the requirements of this approval.
FM
The product meets the requirements of the standards:
● Factory Mutual Approval Standard Class Number 3611
● FM Hazardous (Classified) Location Electrical Equipment:
Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and
Non Incendive / Class I / Zone 2 / Group IIC / T4
Note
Only variants with 24 VDC power supply meet the requirements of this approval.
C-Tick
The product meets the requirements of the AS/NZS 2064 standard (Class A).
cULus Approval for Information Technology Equipment
cULus Listed I. T. E.
Underwriters Laboratories Inc. complying with
● UL 60950-1 (Information Technology Equipment)
● CSA C22.2 No. 60950-1-03
Report no. E115352
Note
Only variants with 24 VDC power supply meet the requirements of this approval.