Connecting The 100 To 240 V Ac Power Supply With The Xr-300M Poe; Signaling Contact; 24 Vdc Signaling Contact - Siemens SCALANCE X-300 Series Operating Instructions Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-300 Series:
Table of Contents

Advertisement

Connecting

6.7 Signaling contact

6.6.2.8

Connecting the 100 to 240 V AC power supply with the XR-300M PoE

Connecting to the power supply
The devices have a single power supply (1 x 100 to 240 V).
The power supply is connected using a 2-pin plug-in terminal block.
Terminal block assignment (2-pin)
Table 6-15
Assignment
To wire up the power connector, use a copper cable of category 18-12 AWG or cable with a
cross-section of 0.75 to 2.5 mm².
6.7
Signaling contact
6.7.1

24 VDC signaling contact

Connecting the signaling contact
The signaling contact is connected to a 2-pin plug-in terminal block.
140
Pin assignment of the 100 to 240 VAC power supply
Labeling
Operating Instructions, 11/2019, A5E01113043-24