Scalance X-300 Declaration Of Conformity; Overview Of Xr-300M Poe Approvals; Mechanical Stability In Operation - Siemens SCALANCE X-300 Series Operating Instructions Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-300 Series:
Table of Contents

Advertisement

11.7.1.2

SCALANCE X-300 declaration of conformity

You will find the EC Declaration of Conformity for these products on the Internet at the following
address:
SCALANCE X-300 declaration of conformity
support.industry.siemens.com/cs/ww/en/ps/15296/cert)
1. Click on the entry "SCALANCE X-300 managed" in the navigation panel at the top edge of
the window and from the drop-down list that opens, select the entry for your product group.
2. Select the entry "Certificate" from the "Entry type"drop-down list.
Result: A list of the available certificates is displayed.
11.7.1.3

Overview of XR-300M PoE approvals

Table 11-7
Overview of the approvals
Device
Variant
1 x 24 VDC
XR324‑4M
1 x 100 to
PoE
240 VAC
1 x 24 VDC
XR324‑4M
PoE TS
For temperature information "T.." or the maximum ambient temperature "Ta:..", refer to the type plate.
1
11.7.1.4

Mechanical stability in operation

The switch meets the following requirements for mechanical stability:
IEC 60068-2-6 (vibration)
● Mounting in the rack: (2-point mounting:)
10 to 58 Hz: 0.075 mm
85 – 150 Hz: 1 g
1 octave/min, 20 sweeps
● Individual mounting: (4-point mounting):
5 to 8.51 Hz: 3.5 mm
8.51 – 500 Hz: 1 g
1 octave/min, 20 sweeps
IEC 60068-2-27 (shock)
● Mounting in the rack (2-point mounting):
15 g, 11 ms duration, 6 shocks per axis
SCALANCE X-300
Operating Instructions, 11/2019, A5E01113043-24
c‑UL‑us
c‑UL‑us
Inf. Tech.
for Hazard‐
Eq.
ous Loca‐
tions
1)
(https://
c‑UL‑us
FM
1)
Ind. Cont.
Eq.
Certifications and approvals
11.7 Product group XR-300M PoE
C‑TICK
CE
ATEX95
Zone 2
1)