Other Properties - Siemens SCALANCE X-300 Series Operating Instructions Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-300 Series:
Table of Contents

Advertisement

Technical specifications
8.8 XR-300M PoE technical specifications
Figure 8-5
8.8.5

Other properties

Switching properties
Max. number of learnable addresses
Aging time
Switching technique
Latency
Reconfiguration times for redundancy mechanisms
Redundancy mechanism
HRP
Standby link
MRP
Mean time between failure (MTBF)
The value in the following table applies to the basic device without media modules.
MTBF
This value applies at 40 °C.
1)
In the calculation of the MTBF of a modular switch, the standard parts count applies; in other
words, the reciprocals of all component failure rates are added.
The reciprocal of this total id the MTBF of the entire assembly.
200
1
P1
P2
P3
P4
P9
P10
P11
P12
1 Gbit/s
Block architecture of the XR324‑4M
2
P5
P6
P7
P8
P13
P14
P15
P16
1 Gbit/s
8000
30 sec
Store and forward
5 μs
Reconfiguration times
300 ms
300 ms
200 ms
> 15 years
1)
Operating Instructions, 11/2019, A5E01113043-24
3
1
2
P1
P2
P1
P2
3
4
P1
P2
P1
P2
SCALANCE X-300

Advertisement

Table of Contents
loading

Table of Contents