Device:
transceiver
SFP992-1LH
SFP992-LH+
SFP992-1ELH
8.10.2

Connectors and electrical data

Table 8-113 Connection of end devices or network components
Device:
(Variant)
Transceiver
SFP991-1
(1 x 100 Mbps, LC port op‐
tical, multimode glass, up
to max. 3 km)
SFP991-1LD
(1 x 100 Mbps, LC port op‐
tical, single mode glass, up
to max. 26 km)
SFP991-1LH+
(1 x 100 Mbps, LC port op‐
tical, single mode glass, up
to max. 70km)
SFP992-1
(1 x 1000 Mbps, LC port
optical, multimode glass,
up to max. 750m)
SFP992-1+
(1x 1000 Mbps, LC port op‐
tical, multimode glass, up
to max. 2 km)
SFP992-1LD
(1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 10km)
SFP992-1LH
(1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 40km)
SFP992-LH+
(1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 70km)
SFP992-1ELH
(1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 120km)
SCALANCE X-300
Operating Instructions, 11/2019, A5E01113043-24
(Variant)
(1 x 1000 Mbps, LC port opti‐
cal, single mode glass, up to
max. 40km)
(1 x 1000 Mbps, LC port opti‐
cal, single mode glass, up to
max. 70km)
(1 x 1000 Mbps, LC port opti‐
cal, single mode glass, up to
max. 120km)
Connection of end devices or network components
Max. num‐
ber
2
2
2
2
2
2
2
2
2
Operating tem‐
Storage/trans‐
perature
port temperature
-40 °C through
-40 °C to +85 °C
+85 °C
-40 °C through
-40 °C to +85 °C
+85 °C
-40 °C through
-40 °C to +85 °C
+85 °C
of which:
electrical
- optical
over FO cable
-
1 x LC port
(100 Mbps)
-
1 x LC port
(100 Mbps)
-
1 x LC port
(100 Mbps)
-
1 x LC port
(1000 Mbps)
-
1 x LC port
(1000 Mbps)
-
1 x LC port
(1000 Mbps)
-
1 x LC port
(1000 Mbps)
-
1 x LC port
(1000 Mbps)
-
1 x LC port
(1000 Mbps)
Technical specifications
8.10 SFP technical specifications
Relative humidity
Operating alti‐
at 25 °C during
tude at max. xx
operation, maxi‐
°C ambient tem‐
mum
perature
<= 95%
2000 m at max.
(no condensa‐
56 °C
tion)
3000 m at max.
50 °C
<= 95%
2000 m at max.
(no condensa‐
56 °C
tion)
3000 m at max.
50 °C
<= 95%
2000 m at max.
(no condensa‐
56 °C
tion)
3000 m at max.
50 °C
Single
Multi
mode
mode
-
-
-
-
-
-
-
-
-
213