7.16

Cable lengths

The cable lengths listed below apply to the SCALANCE XC-200.
Cable
IE TP torsion cable
with IE FC Outlet RJ-45 + 10 m TP cord
IE TP torsion cable
with IE FC RJ-45 Plug 180
IE FC TP Marine / Trailing / Flexible cable
with IE FC Outlet RJ-45 + 10 m TP cord
IE FC TP Marine / Trailing / Flexible cable
with IE FC RJ-45 Plug 180
IE FC TP standard cable
with IE FC Outlet RJ-45 + 10 m TP cord
IE FC TP standard cable
with IE FC RJ-45 Plug 180
7.17

Switching properties

The switching properties listed below apply to the SCALANCE XC-200. The SCALANCE XC-
200 gigabit variants (Page 6) differ from the other SCALANCE XC-200 devices in some
switching properties.
Switching properties
Aging time
Maximum frame size
Max. number of learnable ad-
dresses
Response to LLDP frames
Response to spanning tree
BPDU frames
CoS acc. to IEEE 802.1Q
QoS priority queues
Switching technique
Latency
Full wire speed switching
Frame length (bytes)
64
128
256
SCALANCE XC-200
Operating Instructions, 04/2018, C79000-G8976-C442-04
Permitted cable length
0 to 45 m
+ 10 m TP cord
0 to 55 m
0 to 75 m
+ 10 m TP cord
0 to 85 m
0 to 90 m
+ 10 m TP cord
0 to 100 m
SCALANCE XC-200
Can be configured (default value: 30 seconds)
1632
8192
4
Store and forward
10 microseconds
Number of frames per second (at 100 Mbps)
148810
84459
45290
Technical specifications
7.16 Cable lengths
SCALANCE XC-200G
2048
16000
Blocking
Forwarding
Yes
8
85