Technical specifications
8.6 XR-300M EEC technical specifications
Table 8-61
Device version
(power supply)
24 to 48 VDC
100 to 240 VAC / 60 to
250 VDC
Table 8-62
Device version
(power supply)
1 x 24 to 48 VDC
2 x 24 to 48 VDC
1 x 100 to 240 VAC / 60 to
250 VDC
2 x 100 to 240 VAC / 60 to
250 VDC
Table 8-63
General
In the application range of EN 60255-27
8.6.3

Cable lengths

Table 8-64
Cable type
IE TP torsion cable
IE FC TP Marine Cable
IE FC TP Trailing Cable
IE FC TP Flexible Cable
IE FC TP standard cable
184
Electrical data: Signaling contact
Voltage via signaling con‐
tact
24 VDC
240 VAC
60 VDC
125 VDC
250 VDC
Plug-in terminal block for connectors of the power supply and signaling contact
Power supply
1 x 4-pin
2 x 4-pin
1 x 3-pin
2 x 3-pin
Overvoltage category
Permitted cable lengths (copper cable - Fast Ethernet)
Accessory (plug, outlet, TP cord) Permitted cable length
with IE FC Outlet RJ-45
+ 10 m TP cord
with IE FC RJ-45 Plug 180
with IE FC Outlet RJ-45
+ 10 m TP cord
with IE FC RJ-45 Plug 180
with IE FC Outlet RJ-45
+ 10 m TP cord
with IE FC RJ-45 Plug 180
Switching capacity
(resistive load)
max. 0.1 A
max. 5 A
max. 0.4 A
max. 0.22 A
max. 0.11 A
Signaling contact
1 x 2-pin
2 x 2-pin
1 x 3-pin
2 x 3-pin
Overvoltage category II
Overvoltage category III
0 to 45 m
+ 10 m TP cord
0 to 55 m
0 to 75 m
+ 10 m TP cord
0 to 85 m
0 to 90 m
+ 10 m TP cord
0 to 100 m
Operating Instructions, 11/2019, A5E01113043-24
Resistor between
F1-F2
< 8 Ω