Options Section Of Part Number - York MILLENIUM YCAS Series Installation Operation & Maintenance

Air-cooled screw liquid chillers
Table of Contents

Advertisement

OPTIONS SECTION OF PART NUMBER

16 17 18 19
POWER FIELD
M D
: MP NF Disconnect Switches
M B
: MP Supply w/ Ind. Sys. Brkr & L. Ext. Handles
S B
: SP Supply TB w/ Ind. Sys. Brkr. & L. Ext. Handles
D B
: SP NF Discnct. w/ Ind. Sys. Brkr & L. Ext. Handles
S
X
: SP Supply TB
S D
: SP NF Disconnect Switch
B
X
: SP Circuit Breaker w/ Lockable Handle
C
: Control Circuit Power Terminal Strip
X
: No Option
MP = Multiple Point
SP = Single Point
NF = Non-Fused
TB = Terminal Block
Ser. = Service
Ind. Sys. Brkr. & L. Ext. Handles = Individual System Breaker & Lockable External Handle
38 39 40 41 42 43 44
EVAP. FIELD
3
: 300 PSIG DWP Waterside
D
: Double Thick Insulation
W
: Weld Flange Kit
V
: Victaulic Flange Kit
S
: Flow Switch
M
: Multinat'l Vessel & Assoc.Safety Codes
A
: ASME Pressure Vessel & Associated Codes (American)
S
: AS 1210 Vessel & Associated Codes (Australian)
F
: French Vessel & Associated Codes (DRIRE)
T
: German TUV Vessel & Associated Codes (A.D.
I
Merkblatter)
P
: Italian Vessel & Associated Codes (ISPESL)
R
: Polish Vessel & Associated Codes
X
: Remote DX Cooler
: No Option
NOTES:
1. Q :DENOTES SPECIAL / S.Q.
2. # :DENOTES STANDARD
3. X :w/in OPTIONS FIELD, DENOTES NO OPTION SELECTED
20 21 22 23 24 25 26 27 28
CONTROLS FIELD
X
: No Option
Y
: BAS/EMS Temp Reset / Offset
C
: BAS/EMS Current Reset / Offset
B
: BAS/EMS Both Temp. & Current
M
: Millennium Controls
S
: Spanish LCD & Keypad Display
F
: French LCD & Keypad Display
G
: German LCD & Keypad Display
X
: No Option
L
: N Amer. Safety Code (cU.L./cE.T.L.)
C
: European Safety Code (C.E.)
X
: No Option
P
: Pump Control
R
: Remote Control Panel
S
: Seq. Cntrl & Automatic Lead Trans.
45 46 47
48 49 50 51 52 53 54
CONDENSER FIELD
CABINET FIELD
X
: Aluminum
1
:Copper
C
2
:BlackFin
B
3
:Phenolic
P
4
:TEAO Fan
X
5
Motors
6
7
8
E
X
B
29 30 31 32 33 34 35 3637
COMPRESSOR / PIPING FIELD
#
#
: Low Temp Brine (LBrT)
: Thermal Storage
T
S
: Chicago Relief Code
C
G
: Mechanical Gauge Kit
: Wire (Full Unit) Enc. Panels (factory)
: Wire (Full Unit) Enc. Panels (field)
: Wire/Louvered Enc. Panels (factory)
: Wire/Louvered Enc. Panels (field)
: Louvered (Cond. Only) Enc. Panels (factory)
: Louvered (Cond. Only) Enc. Panels (field)
: Louvered (Full Unit) Enc. Panels (factory)
: Louvered (Full Unit) Enc. Panels (field)
: Compressor Sound Enclosure
: No Option
: Acoustic Sound Blanket
L
: Low Sound Fans
H
: High Static Fans
S
: Final Overspray Paint
1
: 1" Deflection
S
: Seismic
N
: Neoprene Pads

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents