10.9.2 Document Scanning at Platen (IIT)
By the torque from the Carriage Motor, the Carriage Assy in the IIT moves at the shifting speed
corresponding to the set magnification to illuminate the document by the exposure lamp and to capture
the reflected light by the CCD Image Sensor through the multiple mirrors and the lens.
Carriage Assy
IIT
Mirror 2
Mirror 4
Lens
CCD Image Sensor
10 – 21
Document
Document
Mirror 3
Mirror 1
Mirror 5
Carriage Assy
Chapter 10 Machine Overview
ADF
Carriage Assy
Exposure Lamp
MiA06002GA