- Fire3 Test
This test executes IJAC or JBIG which is built in Fire3.
The result "Check OK" or "Check NG" is shown after "Now Checking" is displayed.
- Fire3 IJAC Test
Generates accesses to the Fire3 IJAC. Execute this test when the Fax relation and Scanner relation errors
occurred.
- Fire3 IBIG Test
Generates accesses to the Fire3 IBIG. Execute this test when the Fax relation and Scanner relation errors
occurred.
- Relay/ Signal Test
- Relay Test
A test that switches the relay circuit between the FAX and telephone lines.
- Relay Toggle Test
A test that switches the relay circuit between the FAX and telephone lines at a predetermined cycle.
Toggle test value can be set in the range of 50 to 9999, and the toggle interval is 10ms.
For instance, when the value is set to 100, switching is performed every 1000ms.
- Relay Set
A test that connects the relay circuit selectively to the FAX or telephone line.
Set ON (open)
Set OFF (close)
- Hook Test
A test that switches the telephone line between the on-hook and off-hook states.
- Hook Toggle Test
A test that switches the telephone line between the on-hook and off-hook states at a predetermined cycle.
Toggle test value can be set in the range of 50 to 9999, and the toggle interval is 10ms.
For instance, when the value is set to 100, switching is performed every 1000ms.
- Hook Set
A test that switches the telephone line selectively to the on-hook or off-hook state.
Set ON (on-hook)
Set OFF (off-hook)
- Single Tone Test
Checks the tone output for each single tone for tone dialing. Below are the single tone frequencies (Hz):
0/400/462/1100/1300/1500/1650/1850/2100/500/600/900/1000
Connected selectively to the FAX line.
Connected selectively to the telephone line.
Connected selectively to the on-hook circuit.
Connected selectively to the off-hook circuit.
6 – 73