Fuji Xerox DocuPrint CM305 df Service Manual page 699

Hide thumbs Also See for DocuPrint CM305 df:
Table of Contents

Advertisement

Chain
Description
-Link
825-028
Busy Tone Frequency
825-029
Busy Tone Pattern
Permit/Prohibit Busy Tone
825-030
Detection when calling out
825-031
Resend Quantity
825-032
Redial Quantity
825-033
Max Redial Quantity
825-034
Redial Interval
825-035
FAX Communication Interval
Check the same destination to
825-036
re-call out
Interval between calls-out to the
825-037
same destination
825-045
Ring Threshold
825-046
Complex
825-047
DCCurve
825-048
Rmake
825-049
FastEdgePulseDial
Name
BUSYTONE_FREQ
BUSYTONE_PATTERN
BUSYTONE_DETECTION
NUMBER_OF_RESEND
NUMBER_OF_REDIAL
NUMBER_OF_REDIAL_MAX
INTERVAL_OF_REDIAL
COMM_INTERVAL
CAPAB_NUM_CHECK
NUM_CHECK_TIMER
DAA_REG730
DAA_REG731
DAA_REG733
DAA_REG734
DAA_REG74F
Value Label
Default
0:400Hz
1:350Hz ~ 450Hz
2:300Hz ~ 500Hz
3
3:450Hz ~ 650Hz
4:245Hz ~ 650Hz
0:ON/OFF 0.4 ~ 0.6s
(twice)
1:ON/OFF 0.2 ~ 0.3s(4
times), ON/OFF 0.4 ~
0.6s(twice)
2:ON/OFF 0.2 ~ 0.3s(4
times)
3:ON/OFF 0.12 ~ 0.44s
(3 times)
1
4:ON/OFF 0.3 ~ 0.8s
(twice)
5:ON/OFF 0.2 ~ 0.6s
(twice)
6:ON/OFF 0.5 ~ 1s
(twice)
7:ON/OFF 0.12 ~ 1.2s
(twice)
8:ON 800 ~ 1.2S,OFF 3.2
~ 4.8s(twice)
0:Prohibit
1
1:Permit
1
0 ~ 5: 0 to 5
0 ~ 9: 0 to 9
3
14
0 ~ 255: 0 to 255
1
1 ~ 15:1min ~ 15min
3 ~ 255:3s ~ 255s
8
1S/step
0:OFF
1
1:ON
60
1 ~ 255:1s ~ 255s
0xE8
0x00 ~ 0xFF
0x02
0x00 ~ 0x02
0x02
0x00 ~ 0x04
0x01
0x00 ~ 0xFF
0x00 ~ 0x01
0x01
6 – 53
Chapter 6 General
Details
Access
Busy Tone Detectable
CE
Frequency setting
Busy Tone Detectable Pattern
CE
setting
Busy Tone Detection setting
CE
Re-call out this system-data-
specified number of times when
any of the conditions is met.
【Busy Tone Detection
"Prohibited"】
・An error has occurred during
FAX communication.
CE
【Busy Tone Detection
"Permitted"】
・An error has occurred during
FAX communication.
・Over with no response from
the other party.
Re-call out this system-data-
specified number of times when
any of the conditions is met.
【Busy Tone Detection
"Prohibited"】
・Over with no response from
USER
the other party.
【Busy Tone Detection
"Permitted"】
・Over by detecting busy tone.
CE
USER
Interval time between
independent communications.
There is always this system-
USER
data-specified length of time
between one call-out and
another.
CE
CE
DAA Register 730 setting
CE
DAA Register 731 setting
CE
SiDAA Register 733 setting
CE
SiDAA Register 734 setting
CE
SiDAA Register 74F setting
CE
OFF/
ON

Advertisement

Table of Contents
loading

Table of Contents