Multitest With The Key Cluster; Display Of The Machine Class; Display Of The Software Date - DURKOPP ADLER 550-12-24 Instructions For Operating Manual

Engineered sewing station for pre-ruffling of upholstery pieces
Table of Contents

Advertisement

Available languages

Available languages

5. Multitest with the Key Cluster

5.1 Display of the Machine Class

5.2 Display of the Software Date

If the "Y" is held pressed when the machine is turned on, the test mode
is activated.
The following test programs can be selected :
1. Display of the machine class
2. Display of the software date
3. Input change
4. Switching of the individual outputs
5. Display of the pedal positions
6. Display of the current rpm
7. Display of the current counter status (position)
Order of operations
When turning on the sewing machine, hold the "Y" key down.
The test mode is activated.
The following display appears:
Release the "Y" key.
The first test display appears.
With each pressing of the "Y" key there is an advance to the next
test program.
After the 7th test program the first test program appears again.
The testing program is ended by turning off and on.
No entries can be made in this test program. It only shows the
machine class, e.g.:
Order of operations
Turn on the test mode (see Chapter 5).
Advance to the desired program by pressing the "Y" key.
No entries can be made in this test program. It only shows the date of
the software, e.g.:
Order of operations
Turn on the test mode (see Chapter 5).
Advance to the desired program by pressing the "Y" key.
3