Remote Access; Overview; Searching For Devices In The System Network - Siemens SINUMERIK 840D sl Commissioning Manual

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Service and diagnostics

6.5 Remote access

6.5
Remote access
6.5.1

Overview

You can use a remote connection to access other devices via the network:
● Access to maintenance with prompt (SSH) via PuTTy or WinSCP
● Access via VNC Viewer with all its operator and maintenance options, which are also
available directly on the PCU.
See also
Setting up and using SSH (Page 93)
6.5.2

Searching for devices in the system network

The "sc_show_net" command shows devices available in the system network in the prompt
and offers additional information about these devices.
As both these functions rely on SNMP (Simple Network Management Protocol), only SNMP-
capable device will be found. In the case of Windows-based devices, this depends on the
software version. If a simple call is made, without any additional options, a list of the devices
found will appear showing the relevant IP address, DNS name (if known), and a short
description (module name).
Command sc_show_net
This command is called up in the DOS shell:
Syntax:
Authorization level:
90
sc_show_net [-xml] [-hw|-tco|-sw|-swfull|-loc|-panel| -dhcp|-
switch|-all] [HOSTS...]
None
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
PCU Base Software (IM10)

Advertisement