Agilent Technologies N5230AU/CU-971 Installation Note page 26

Extended frequency range upgrade kit to upgrade option 220 to option 420
Table of Contents

Advertisement

Step 10. Install the New Test Set Deck Front Panel
Refer to
Figure 15
for this procedure. New parts are listed in
1. Place the new test set deck front panel, with the LED board and both new couplers
attached, onto the test set deck as shown.
2. Using a T-10 TORX driver, loosely reinstall the eight screws (items
the front panel to the test set deck. Once all screws have been loosely installed, torque each
of the eight screws to 9 in-lbs in the order indicated (
ensure proper alignment.
3. Reconnect the wrapped wire cable (item
Figure 15 Test Set Deck Front Panel Installation
26
Table 1 on page
through
) to the front-panel LED board.
Installation Note N5230-90010
7.
through
) to secure
). This is important to

Advertisement

Table of Contents
loading

Table of Contents