B. SEE THROUGH
Figure 4.2
IMPORTANT: FIREPLACE IS NOT LOAD-BEARING.
B

SEE THROUGH

Model #
A
55-3/4
FDN-4-ST
[1,416]
67-3/4
FDN-5-ST
[1,721]
79-3/4
FDN-6-ST
[2,026]
91-3/4
FDN-7-ST
[2,330]
Heat & Glo • FDN-4-ST, FDN-5-ST, FDN-6-ST, FDN-7-ST Installation Manual • 16400-9801 Rev. H • 11/19
MINIMUM NON-COMBUSTIBLE ZONE
A
IMPORTANT FRAMING NOTES:
FRAMING SHOULD BE BUILT AFTER THE FIREPLACE IS INSTALLED OR EXTRA CLEARANCE MUST
BE PLANNED FOR AT THE INTAKE COLLAR AND FOR THICKNESS OF MATERIALS USED.
B
C
FRAMING DIMENSIONS ASSUMING 1/2" [13] DRYWALL AND NON-COMBUSTIBLE BOARD USED.
56
23
[1,422]
[584]
THESE DIMENSIONS REPRESENT THE FRAMING DIMENSIONS FOR COMBUSTIBLE MATERIAL.
56
23
NON-COMBUSTIBLE FRAMING AND FINISHING MATERIALS MAY BE USED WITHIN THESE DIMENSIONS
[1,422]
[584]
RIGHT UP TO THE UNIT.
56
23
NO COMBUSTIBLE MATERIAL WITHIN 6" [152] OF THE TOP OF THE FIREPLACE.
[1,422]
[584]
NO COMBUSTIBLE MATERIAL WITHIN 1" [25] OF THE SIDES OF THE FIREPLACE.
56
23
[1,422]
[584]
COMBUSTIBLE MATERIAL SHALL NOT BE PLACED DIRECTLY ON THE FACE OF THE FIREPLACE, TOP
AND SIDES.
SEE SECTION 10 (FINISHING) FOR DETAILS REGARDING 1/2 INCH STANDOFFS.
STEEL SURFACE MAY BE COVERED WITH NON-COMBUSTIBLE FINISHING MATERIAL.
1" [25] CLEARANCE TO THE B-VENT MUST BE MAINTAINED.

4 - FRAMING

OPEN AIR SPACE
6" [25]
1/2" Standoffs
(Both Sides)
COMBUSTIBLE OR NON-COMBUSTIBLE
BACKING MATERIAL (I.E. SHEETROCK)
ON BOTH SIDES
C
11