Heat & Glo FB-GRAND-S Owner's Manual
Heat & Glo FB-GRAND-S Owner's Manual

Heat & Glo FB-GRAND-S Owner's Manual

Hearth and home gas inserts owner's manual installation and operation
Hide thumbs Also See for FB-GRAND-S:
Table of Contents

Advertisement

Model(s):
FB-GRAND-S
FB-IN-S
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber
or gas fi tter;
• a CO detector shall be installed in the room where the
appliance is installed.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo FB-GRAND-S

  • Page 1 CAN/CSA Z240MH. This appliance is only for use with the type(s) of gas indicated on the rating plate. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 CAUTION DO NOT DISCARD THIS MANUAL • Read, understand and follow these instructions for safe installation and operation.
  • Page 2 MAX. INPU T BTUH: MIN. INPU T BTUH: ORIFICE SIZE: Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 Congratulations This Owner’s Manual should be retained for future reference. We suggest that you keep it with your other important documents and product manuals.
  • Page 3: Table Of Contents

    C. Placing, Securing and Leveling the Appliance ..13 D. Installing Adaptor and Termination Cap ....14 Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 Table of Contents 8 Gas Information A.
  • Page 4: Listing And Code Approvals

    34,000 FB-IN-S (LP) 31,000 CANADA Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 C. High Altitude Installations U.L. Listed gas appliances are tested and approved with- out requiring changes for elevations from 0 to 2000 feet in the U.S.A.
  • Page 5: Getting Started

    Tape measure Non-corrosive leak check solution 1/2 - 3/4 inch length, #6 or #8 Self-drilling screws Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 C. Inspect Appliance and Components WARNING Inspect appliance and components for damage.
  • Page 6: Inspect Firebox

    • Cracks that penetrate entirely through the firebrick material. Inspection for cracking should be run when the appliance is cool. Cracks tend to close as the appliance heats up. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08...
  • Page 7: Fireplace Size Requirements

    fi replace height for bends in vent pipe. Figure 3.1 Fireplace Opening Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 • The metal fl oor of the solid fuel fi rebox may be removed to facilitate the installation of the insert. The appliance may...
  • Page 8: Clearances

    fi rebox. WARNING Fire Risk. • Locate and install appliance to all clearance specifi cations in manual. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 INLET AIR 12 in. MAX. EXHAUST VENT PIPE...
  • Page 9: Termination Locations

    Over 18/12 to 20/12 ...7.5 Over 20/12 to 21/12 ...8.0 * 3 foot minimum in snow regions Figure 4.1 Minimum height from roof to lowest discharge opening Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 HORIZONTAL OVERHANG VERTICAL WALL...
  • Page 10: Vent Information And Diagrams

    Figure 5.1 Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 Fire Hazard. Explosion Risk. Asphyxiation Risk. Do NOT connect this gas appliance to a chimney fl...
  • Page 11: Installation Preparation

    • Local building codes required by authority having jurisdiction. • NFPA 211 Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 E. Fireplace Conversion Notice Permanently attach the label with the following warning to the inside lower back of the fi replace fi rebox into which the insert is being installed.
  • Page 12: Installing Vent Pipe And Appliance

    Figure 7.1 Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 B. Connecting Vent Pipe Reference instructions in the termination kit. • Install the 3-inch fl exible vent pipe(s) down through the chimney.
  • Page 13: Placing, Securing And Leveling The Appliance

    • Attach surround. Follow instructions accompanying surround. • Push insert so that surround becomes tight against face of fi replace. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 SEALANT ADHESIVE Failure to position the parts in accordance with these diagrams or failure to use only parts specifi...
  • Page 14: Installing Adaptor And Termination Cap

    Installation TERMINATION EXHAUST VENT PIPE INLET AIR VENT PIPE Figure 7.4 Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 HORIZONTAL OVERHANG Damper Flashing Kit (Optional) For use with LINK-DV4-30B Liner Kit. VERTICAL WALL Note: Damper may have to be removed to use this kit.
  • Page 15: Gas Information

    3.5 inches Manifold pressure w.c. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 C. Gas Connection Note: Have the gas supply line installed in accordance with local building codes, if any. If not, follow ANSI 223.1.
  • Page 16 • This valve has been preset at the factory. • Changing valve settings may result in fi re hazard or bodily injury. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 HIGH ALTITUDE INSTALLATIONS U.L. Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A.
  • Page 17: Electrical Information

    STANDING PILOT VALVE Figure 9.1 Standing Pilot Ignition Wiring Diagram Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 Appliance Requirements • This appliance DOES NOT require 110-120 VAC to operate. • It is recommended that a 110 VAC junction box be connected for use with fan or remote control.
  • Page 18: Junction Box Installation

    • Replace damaged wire with type 105º C rated wire. • Wire must have high temperature insulation. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 C. Installation for Fan (Optional) On units already installed removal of decorative front, INSERT STRAIN RELIEF surround and gas insert is required.
  • Page 19 WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE C RATED WIRE. Figure 9.4 Fan Wiring Diagram Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 JUNCTION BOX GROUND 110-120 VAC BEND...
  • Page 20: Finishing

    TOP OF DOOR Figure 10.2 Clearances to Mantels or other Combustibles above Appliance when using Galleria or Halston Doors Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 B. Installing Trim Surrounds Combustible materials MUST NEVER overlap onto the front face.
  • Page 21: Appliance Setup

    • Replace ember material annually. Improperly placed embers interferes with proper burner operation. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 Placing the Ember Material Ember material is shipped with this gas appliance. To place the ember material: •...
  • Page 22: Positioning The Logs

    Please refer to grate assembly. LOG NUMBER 1 (SRV768-701): B and D. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 Logs 5 Locating Tabs Grate Assembly Place log #1 onto the grate. Push log back until it rests against locating tabs...
  • Page 23 LOG NUMBER 4 (SRV582-705): #4 placed on log #1. The back of log #4 should make contact with the back of the fi rebox. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 .75 in. Position log #2 onto grate such that tabs A and C fi t into the slots on bottom Position log #3 onto grate such that tab E fi...
  • Page 24: Log Placement Instructions

    Position log #1onto the grate such that grooves on bottom of log #1 mate with grate. Push log back until it rests against locating tabs A and B. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 (Model: FB-IN-S)
  • Page 25 LOG #4 (SRV573-702): Place log #4 into the fl at spot on the log #1 and the left side of the log will rest on log #2 as shown. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08...
  • Page 26: Glass Assembly

    (see Figure 11.16). Replacing Glass Assembly Replace the glass door on the appliance. Fasten the latches on the glass frame. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 FIREBOX SURROUND LOCATING TABS Figure 11.16 Glass Assembly G.
  • Page 27: Operating Instructions

    Gas may build up while lighting pilot. • Remove glass assembly before lighting pilot. • Replace glass assembly after lighting pilot. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down.
  • Page 28: Lighting Appliance

    For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 • If you cannot reach your gas sup- plier, call the fi re department.
  • Page 29: Check Pilot Flame Appearance

    • Replace cap screw and seal to prevent gas leaks. • Check for gas leaks after tightening. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 D. After Appliance is Lit WARNING Glass door must be in place when appliance is operating.
  • Page 30: Frequently Asked Questions

    Metallic noise Is it normal to see the pilot fl ame burn continually? Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 Smoke and odors released during initial operation. Smoke and odors may be irritating to sensitive individuals.
  • Page 31: Troubleshooting

    ON position. b. Thermopile may not be gener- ating suffi cient millivoltage. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 Corrective Action Check the spark at the electrode and pilot. If no spark and electrode wire is properly connected, replace the ignitor.
  • Page 32 7. Flame burns blue a. Insuffi cient oxygen being supplied. and lifts off burner. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 Possible Cause Turn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter a the thermopile terminals.
  • Page 33: Maintaining And Servicing Appliance

    • Fire • Delayed ignition or explosion • Exposure to combustion fumes • Odors Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 CAUTION Handle glass assembly with care. NOTE: Clean glass after initial 3-4 hours operation.
  • Page 34 2. Replace batteries in remote transmitters and battery-powered receivers. 3. Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure or leaking. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 Maintenance Tasks...
  • Page 35: Reference Materials

    80 mm GAS INLET 1-9/16 in. 6-5/8 in. 40 mm 169 mm Location Figure 15.1 Appliance Dimensions Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 2-1/2 in. 64 mm MODEL DIMENSIONS FB-GRAND-S Inches Millimeters Inches 22-1/2...
  • Page 36: Vent Kits Components

    FLEX3-30/2: Two 3 inch fl exible liners expands to 30 feet each. FLEX-CNCT: Connector kit - 3 inch liner to 3 inch liner, one connector per kit. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 FLASH-DAMP LINK-ZC-ADP SVRLINK-ADP...
  • Page 37: Service Parts

    FB-GRAND-S C. Service Parts Service Parts Diagram Beginning Manufacturing Date: Oct. 2007 Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08...
  • Page 38 Conversion Kit LP Regulator NG Regulator LP Pilot Orifi ce NG Pilot Orifi ce LP Additional service part numbers on following page. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 FB-GRAND-S COMMENTS PART NUMBER LOGS-CFXGB SRV768-701...
  • Page 39: Log Set Assembly

    FB-IN-S Service Parts Beginning Manufacturing Date: Oct. 2007 Service Parts Diagram Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08...
  • Page 40 Conversion Kit LP Pilot Orifi ce NG Pilot Orifi ce LP Regulator NG Regulator LP Additional service parts on following page. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 COMMENTS PART NUMBER LOGS-CFXINB SRV773-701 SRV773-702 SRV768-704...
  • Page 41 Flex Ball Valve Assembly Valve NG Valve LP Flame Control Knob Pilot Control Knob Bracket: Valve Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 FB-GRAND-S, FB-IN-S Beginning Manufacturing Date: Oct. 2007 Ending Manufacturing Date: ______ COMMENTS FB-GRAND-S...
  • Page 42: Limited Lifetime Warranty

    • Adjustments, regular maintenance, cleaning and temporary repairs, or the failure to duplicate the problem in the home is not covered under this warranty. Page 1 of 2 Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 Wood Pellet...
  • Page 43 If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide necessary parts or components, contact the nearest authorized HHT dealer or supplier. Page 2 of 2 Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 4021-645A 09-01-08...
  • Page 44: Contact Information

    6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. G • 11/08 Heat & Glo, a brand of Hearth & Home Technologies Inc.

This manual is also suitable for:

Fb-in-s

Table of Contents