MODEL #
FDN-4-ST
FDN-5-ST
FDN-6-ST
FDN-7-ST
B. CLEARANCES
WARNING: NON-COMBUSTIBLE ZONE: USE ONLY NON-COMBUSTIBLE MATERIAL IN THIS AREA FOR ENTIRE WIDTH OF
FIREPLACE. DO NOT USE WOOD, SHEETROCK, ETC., IN THIS ZONE. SEE FIGURE 2B.
NOTE: OTHER CLEARANCES APPLY. ALL CLEARANCES MUST BE MAINTAINED.
Refer to Section 5 (Non-Combustible Zone) and Section 10 (Finishing) for more information.

CLEARANCES

From unit left & right sides
To flooring under fireplace
Unit top to ceiling
Unit side to adjacent sidewall
From appliance front*
NO COMBUSTIBLE
MATERIAL WITHIN
1" [25]
OF SIDES OF
FIREPLACE
COMBUSTIBLE
FRAMING AND
FINISHINGMATERIAL
ALLOWED ON THE
FACE OF THE
FIREPLACE BELOW
THE BOTTOM
VIEWING EDGE
ONLY.
Figure 2B
6
Heat & Glo • FDN-4-ST, FDN-5-ST, FDN-6-ST, FDN-7-ST Installation Manual • 16400-9801 Rev. H • 11/19
2 - FIREPLACE SPECIFICATIONS
DESCRIPTION
B-VENT
4X2 SEE THROUGH
8"
5X2 SEE THROUGH
8"
6X2 SEE THROUGH
10"
7X2 SEE THROUGH
10"
NO COMBUSTIBLE
MATERIAL WITHIN 1"
[25]
OTHER CLEARANCES:
DO NOT PLACE ON CARPET, VINYL OR SOFT SURFACES.
A COMBUSTIBLE MANTEL MAY BE PLACED AT THE TOP OF THE GLASS VIEWING AREA. DO NOT OVERLAP GLASS.
A COMBUSTIBLE HEARTH EXTENSION MAY BE USED AT THE BOTTOM OF GLASS VIEWING. DO NOT OVERLAP GLASS.
* MINIMUM DISTANCE RECOMMENDED FROM VIEWABLE SIDES OF APPLIANCE FOR SERVICE ACCESS = 24 IN. [610 mm].
SPECIFICATIONS TABLE
OA
REG PV
10"
PVK-45
10"
PVK-45
10"
PVK-67
10"
PVK-67
NO COMBUSTIBLE
MATERIAL WITHIN 6"
[152] OF THE TOP OF
THE FIREPLACE
6" [152]
1" [25]
FRONT*
IN-LINE
BTU'S
NG ORIFICE
PVI-45
60,000
(3X) #43
PVI-45
80,000
(4X) #43
PVI-67
100,000
(5X) #43
PVI-67
120,000
(6X) #43
1"
0
6"
1"
*See note below
1" [25]
PROPANE
ORIFICE
(3X) #55
(4X) #55
(5X) #55
(6X) #55
25mm
0
122mm
25mm
FRONT*

Hide quick links: