Heat & Glo Foundation Series Installation And Operating Manual page 20

Co-linear direct vent gas fireplaces
Table of Contents

Advertisement

Available In-Line Power Venting
An in-line power vent (PVI-45 or PVI-67) is approved for use with this appliance. It is crucial that all B-Vent pipe and elbow joints, and the longitudinal
seam are sealed using a high temperature RTV Silicone and/or foil tape.
NOTE: All pipe and elbow joints must be sealed. This includes the longitudinal seam on the pipe.
High Temp RTV Silicone and/or foil tape MUST be used on each joint/seam.
Failure to do so may cause lack of vacuum and may not trigger the vacuum switch.
C
2.37 in. (60 mm)
E
E
B
A
D
Figure 8A.5
20
Heat & Glo • FDN-4-ST, FDN-5-ST, FDN-6-ST, FDN-7-ST Installation Manual • 16400-9801 Rev. H • 11/19
D
Fan Type
Motor Type
Voltage
Amperage
Motor Output
G
RPM
Weight
K
Duct Connection (E) in. (mm)
Dimension A
Dimension B
Dimension C
Dimension D
Dimension E
J
Dimension G
Dimension H
Dimension J
Dimension K
Dimension R
R
MODEL
Centrifugal Impeller
(VAC)
Amps
hp (kW)
lbs (kg)
in. (mm)
in. (mm)
in. (mm)
in. (mm)
in. (mm)
in. (mm)
in. (mm)
in. (mm)
in. (mm)
in. (mm)
PVI-45
PVI-67 in.
Centrifugal Impeller
(F-Wheel)
(F-Wheel)
TEFC
1 x 120
2.9
3/7 (.32)
13/16 (.61)
1600
38 (17)
8 (203)
14.57 (370)
16.15 (410)
12.60 (320)
13.98 (355)
9.26 (235)
9.26 (235)
5.52 (140)
7.68 (195)
7.9 (200)
7.9 (200)
15.75 (400)
15.75 (400)
7.10 (180)
7.88 (200)
8.27 (210)
9.26 (235)
5.12 (130)
5.12 (130)
14.57 (370)
16.15 (410)
TEFC
1 x 120
5.3
1600
60 (27)
8 (203)

Hide quick links: