Underwriters
Laboratories Listed
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
- What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
Printed in U.S.A. Copyright 2002,
Heat-N-Glo, a division of Hearth Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
1. This appliance may be installed in an after-
market, permanently located, manufactured
(mobile) home, where not prohibited by lo-
cal codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
Please contact your Heat-N-Glo dealer with any
questions or concerns. For the number of your nearest
Heat-N-Glo dealer, please call 1-888-427-3973.
1
Installers Guide
783-900C 12/02

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo FB-Grand

  • Page 1 Models: Installers Guide FB-Grand FB-IN CFX-Grand-B CFX-IN-B Underwriters Laboratories Listed READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE. THIS INSTALLERS WARNING: IF THE INFORMATION GUIDE MUST BE LEFT WITH APPLIANCE FOR IN THESE INSTRUCTIONS IS NOT FUTURE REFERENCE. FOLLOWED EXACTLY, A FIRE OR...
  • Page 2: Safety And Warning Information

    SAFETY AND WARNING INFORMATION These units MUST use one of the vent systems READ and UNDERSTAND all instructions carefully described in the Installing the Fireplace section of before starting the installation. FAILURE TO the Installers Guide. NO OTHER vent systems or FOLLOW these installation instructions may result components MAY BE USED.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Safety and Warning Information ..........2 Service Parts Lists ..............4 Section 1: Approvals and Codes ..........10 Appliance Certification ............... 10 Installation Codes ..............10 High Altitude Installations ............10 Section 2: Getting Started ............11 Introducing the Heat-N-Glo Gas Appliances .......
  • Page 4: Service Parts Lists

    Service Parts (NG, LP) Exploded Parts Diagram CFX-Grand-B: Manufacturing Dates: 9-01 to 12-02 (GN, PL) Vue éclatée des pièces FB-Grand-B: Manufacturing Dates: 8-02 to _____ FB-GRAND SHOWN Log Set Assembly * Part number list on following page. * Part number list on following page.
  • Page 5 (NG, LP) Service Parts List / Liste des pièces de rechange FB-GRAND IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période.
  • Page 6 (NG, LP) Service Parts List / Liste des pièces de rechange CFX-GRAND-B IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période.
  • Page 7 FB-IN, CFX-IN-B Service Parts (NG, LP) Exploded Parts Diagram CFX-IN-B: Manufacturing Dates: 12-02 to 9-01 (GN, PL) Vue éclatée des pièces FB-IN: Manufacturing Dates: 8-02 to ____ FB-IN SHOWN Log Set Assembly * Part number list on following page. * La liste des numéros de pièce se trouve à...
  • Page 8 Service Parts List / Liste des pièces de rechange FB-IN IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période.
  • Page 9 (NG, LP) Service Parts List / Liste des pièces de rechange CFX-IN-B IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période.
  • Page 10: Section 1: Approvals And Codes

    When installing this appliance at an elevation above 2,000 feet, it may be necessary to decrease the input rating by MODELS: FB-GRAND, FB-IN changing the existing burner orifice to a smaller size. Input CFX-GRAND-B, CFX-IN-B rate should be reduced by 4% for each 1000 feet above a LABORATORY: Underwriters Laboratories 2000 foot elevation in the U.S.A.
  • Page 11: Section 2: Getting Started

    Getting Started Introducing the Heat-N-Glo Gas Appliances 3. To assure top performance, safety and efficiency, inserts must be installed with an approved flue liner as per CAN/ Heat-N-Glo direct vent gas appliances are designed to CGA B-149 or National Fuel Code ANSI Z223 and these operate with all combustion air siphoned from outside of instructions.
  • Page 12 LOWER GRILLE RATING PLATE GAS CONTROL VALVE LOW VOLTAGE WIRES ELECTRICAL JUNCTION BOX ACCESS GAS ACCESS TOP VIEW 2” (50.8mm) MINIMUM FIREPLACE SIZE CFX-GRAND-B and FB-GRAND CFX-IN-B and FB-IN Location Inches Millimeters Inches Millimeters Front Width 30-1/4 768.4 Rear Width 22-5/8 574.7...
  • Page 13 5-9/16 2-1/2 2-1/16 13-3/4 3-1/8 ø 2-13/16 1-1/16 GAS INLET ELECTRICAL 1-9/16 3-9/16 6-5/8 ACCESS (IF EQUIPPED) MODEL DIMENSIONS CFX-GRAND-B and FB-GRAND CFX-IN-B and FB-IN Location Inches Millimeters Inches Millimeters 22-1/2 8-3/4 6-1/2 33-3/4 857.2 29-3/8 746.1 30-9/16 26-1/16 23-7/8...
  • Page 14: Section 3: Installing The Insert

    Vent System Approvals metal pipe. Additionally, the use of kit FLASH-DAMP will Models CFX-Grand-B, CFX-IN-B, FB-IN and FB-GRAND is seal off the damper opening when terminating the inlet air approved with vent termination kits LINK-DV-30, LINK-DV- vent pipe just above the damper.
  • Page 15 Slide the gas insert into place, and position any excess flexible vent pipe back HORIZONTAL OVERHANG up into the chimney. Attach the pipe-to- cap adaptor to the termination cap and to the top of the flexible vent pipe and set VERTICAL WALL the cap in place at the top of the chimney.
  • Page 16 This option shows both exhaust and inlet air vent pipes attached to the adaptor. TERMINATION ADAPTOR EXHAUST COLLAR INLET AIR COLLAR EXHAUST VENT PIPE V= 14 FT. MINIMUM 40FT. MAXIMUM 3 INCH COLLAR (Factory installed to stainless steel section) WARNING: DO NOT BLOCK PIPE END WITH INSULATION OR ANY OTHER SEALING MATERIAL...
  • Page 17 Note: Inspect for exhaust collar gasket to insure LOCKING TABS positive exhaust seal. LOCKING HANDLE TERMINATION ADAPTOR EXHAUST VENT PIPE SUPPLIED WITH TERMINATION KIT INLET AIR VENT COLLAR (LINK-DV30 SHOWN) SLIDING PLATE INLET AIR VENT PIPE 3 INCH STAINLESS STEEL COLLAR ADAPTER FOR EXHAUST (MUST BE INSTALLED)
  • Page 18: Step 2 Positioning, Leveling, And Securing The Insert

    Step 2. Positioning, Leveling, and Step 4. The Gas Supply Line Securing the Insert NOTE: Have the gas supply line installed in accordance Remote Control with local building codes by a qualified installer The receiver for the remotes must be installed BETWEEN approved and/or licensed as required by the locality.
  • Page 19: Step 5 Gas Pressure Requirements

    Pressure w.c. w.c. • Models FB-Grand and FB-IN require 110-120 VAC if op- tional blower is added to the system. Inlet and outlet pressure taps are provided on the front face of the gas control for a test gauge connection to measure WARNING: DO NOT CONNECT 110-120 VAC TO the manifold pressure.
  • Page 20 FROM OUTSIDE OF UNIT FEED PLUG THROUGH HOLE SIDEWALL Fan Option (FB-IN & FB-Grand ONLY) On units already installed removal of decorative front, sur- round and gas insert is required. • Detach flexible liner from back of unit. • Remove the four screws on the coverplate (see Figure 11).
  • Page 21: Step 8 Installing Trim Surround

    Step 7. Installing Logs and Ember Material Shutter Settings BURNER PAN Burner ___________________________________________ CFX-GRAND-B, FB-GRAND 3/8” ___________________________________________ CFX-IN-B, FB-IN 1/2” Positioning the Logs The logs have been packaged separately. Refer to the EMBER MATERIAL installation instructions that accompany this manual. Save...
  • Page 22: Step 9 Before Lighting The Appliance

    Step 9. Before Lighting the Appliance 3. Reconnect the low voltage wires to the ON/OFF switch. 4. Attach surround assembly by hooking the support brack- Before lighting the appliance, be sure to do the following: et on the locating tabs on top of the gas insert fireplace Remove all paperwork from underneath the fireplace.
  • Page 23: Section 4: Maintaining And Servicing Your Appliance

    Maintaining and Servicing Your Appliance Appliance Maintenance Although the frequency of servicing and maintenance will depend on use and the type of installation, you should have a qualified service technician perform an appliance check- up at the beginning of each heating season. See the table below for specific guidelines regarding each fireplace main- tenance task.