Heat & Glo FB-ZC-S Owner's Manual
Heat & Glo FB-ZC-S Owner's Manual

Heat & Glo FB-ZC-S Owner's Manual

Hearth & home technologies gas fireplace owner's manual installation and operation
Table of Contents

Advertisement

Model:
FB-ZC-S
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber
or gas fi tter;
• a CO detector shall be installed in the room where the
appliance is installed.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo FB-ZC-S

  • Page 1 fi tter; • a CO detector shall be installed in the room where the appliance is installed. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 Owner’s Manual Installation and Operation • Leave this manual with party responsible for use and operation.
  • Page 2 (Po. Col. d’eau) IN CANADA Mode l: 0-0000 FT . 0000-0000FT . (Modele): 00,000 00,000 00,000 00,000 Serial #XXXXX #XXXXX (Serie): Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 Model Number MADE IN US A Serial Number XXXXXXXX XXXXXXXX...
  • Page 3: Table Of Contents

    E. Contact Information ......41 = Contains updated information. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08...
  • Page 4: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 WARNING...
  • Page 5: Getting Started

    • Installation and/or use of any component part not approved by Hearth & Home Technologies. Any such action may cause a fi re hazard. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 WARNING Inspect appliance and components for damage.
  • Page 6: Inspect Firebox

    • Cracks that penetrate entirely through the firebrick material. Inspection for cracking should be run when the appliance is cool. Cracks tend to close as the appliance heats up. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08...
  • Page 7: Fireplace Size Requirements

    20-3/8 in. 29-3/4 in. MINIMUM EXISTING WOODBURNING FIREPLACE SIZE Location Inches Front Width 30-7/8 Rear Width 25-5/8 Depth Height 19-1/2 Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 18-15/16 in. GAS INLET (GAS BALL VALVE NOT SHOWN) Millimeters...
  • Page 8: Clearances

    • Locate and install appliance to all clearance specifi cations in manual. MANTEL Figure 3.2 Clearances to Mantels or other Combustibles above Appliance 12 in. MAX. 12 in. MAX. TOP OF UNIT Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08...
  • Page 9: Termination Locations

    * 3 foot minimum in snow regions Figure 4.1 Minimum height from roof to lowest discharge opening HORIZONTAL OVERHANG VERTICAL WALL ROOF PITCH IS X/ 12 H (Min.) Ft. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08...
  • Page 10: Vent Information And Diagrams

    SEAL DAMPER AREA INLET AIR VENT PIPE COLLAR ATTACHMENT BRACKET Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 WARNING Fire Hazard. Explosion Risk. Asphyxiation Risk. Do NOT connect this gas appliance to a chimney fl ue serving a separate solid fuel or gas burning appliance.
  • Page 11: Installation Preparation

    fi rebox of the wood- burning fi replace (see photo below). EXISTING BOTTOM OF Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 WARNING Fire Risk. This fi replace has been converted for use with a gas fi...
  • Page 12: Installing Vent Pipe And Appliance

    (see Figure 7.1). NOTE: The collar slide plate may be removed from appliance to aid installation. • Seal opening between fl ex vent and chimney just above insert. Unfaced fi berglass insulation may be used for this purpose. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08...
  • Page 13 WOOD-BURNING CLASS A PIPE INLET AIR VENT PIPE STAINLESS STEEL ADAPTER FOR EXHAUST (MUST BE INSTALLED) Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 TERMINATION (SQUARE FLASHING REMOVED) EXHAUST VENT PIPE SUPPLIED WITH TERMINATION KIT INLET AIR VENT COLLAR...
  • Page 14: Placing, Securing And Leveling The Appliance

    OR terminate within chimney. • Do NOT allow vent to sag below connection point to appliance. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 WARNING Fire Risk. Only an approved Hearth & Home Technologies surround may be used to cover integral grills on solid fuel burning fi...
  • Page 15: Installing Adaptor And Termination Cap

    VENT PIPE Note: Untwist the pipe while extending it, to achieve full 30’ length. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 Factory Built Wood Burning OPTIONAL LINK-ZC-ADPB FOR USE WITH CLASS A WOODBURNING PIPE Remove 18 inch x 18 inch fl ashing on cap by removing 3 screws.
  • Page 16: Gas Information

    11.0 inches w.c. 14.0 inches w.c. 10.0 inches w.c. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 WARNING Gas Leak Risk • Support control when attaching pipe to prevent bending gas line.
  • Page 17 To identify the proper orifi ce size, check with the local gas utility. If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08...
  • Page 18: Electrical Information

    • If desired an additional wall switch or thermostat may be added to system as shown in Figure 9.1. ON/OFF SWITCH Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 WARNING Wire 110V to electrical junction box. Do NOT wire 110V to valve.
  • Page 19: Junction Box Installation

    • Reinstall the cover plate back on the unit. Make sure the fan does not make contact with the back wall to prevent noise from vibration. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 COVER PLATE ATTACH...
  • Page 20 AND SECURE WITH WING NUT REMOTE VARIABLE SPEED CONTROL RECEPTACLE JUNCTION BOX GROUND 110-120 VAC Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 WING TEMP SWITCH BRACKET BLOWER RECEPTACLE BLOWER NOTE: If any of the original wire as supplied with the appliance must be replaced, it must be replaced with type 105 º...
  • Page 21: Finishing

    MANTEL Figure 10.1 Clearances to Mantels or other Combustibles above Appliance 12 in. MAX. 12 in. MAX. TOP OF UNIT Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08...
  • Page 22: Appliance Setup

    • Save the remaining ember materials for use during appliance servicing. The embers provided should be enough for 3 to 5 applications. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 BURNER PAN...
  • Page 23: Positioning The Logs

    The log should be placed all the way back and in the center of the ledge. FIREBOX LOG #1 Place log #1 on the fi rebox ledge as shown. The front portion of the log should hang Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 FIREBOX LEDGE 2019-700...
  • Page 24 Position log #2 by locating its slot over the tabs on left front of the burner. GROOVE Position log #3 by locating it against tab on right center of the burner. The groove on the Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 GROOVE...
  • Page 25: Glass Assembly

    G. Air Shutter Setting Optimal fl ame appearance is dependent on the air shutter setting. Adjustments should be made by a qualified technician. Burner Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 GLASS ASSEMBLY PULL TO RELEASE...
  • Page 26: Operating Instructions

    Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down.
  • Page 27: Lighting Appliance

    For assistance or additional informa- tion, consult a qualifi ed installer, ser- vice agency or the gas supplier. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 LIGHTING INSTRUCTIONS 1. Turn off all electric power to the appliance.
  • Page 28: Check Pilot Flame Appearance

    This will help avoid setting off smoke detectors, and help eliminate any odors associated with the appliance’s initial burning. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 WARNING Glass door must be in place when appliance is operating.
  • Page 29: Frequently Asked Questions

    This noise does not affect the operation or longevity of the appliance. In a standing pilot system the pilot will always stay on. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 CAUTION • Open windows for air circulation.
  • Page 30: Troubleshooting

    Take a reading at the thermopile leads. The read- ing should be 325 millivolts minimum. Replace the thermopile if the reading is below the minimum. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 Corrective Action...
  • Page 31 Ensure that the glass is tightened properly on the unit, particularly on top corners. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 Corrective Action...
  • Page 32: Maintaining And Servicing Appliance

    Refer to maintenance instructions. • Combustible materials blocking cap may ignite. • Restricted air fl ow affects burner operation. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 CAUTION Handle glass assembly with care. NOTE: Clean glass after initial 3-4 hours operation.
  • Page 33 6. Inspect draft shield to verify it is not bent, damaged or missing. Remote controls 1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. Maintenance Tasks Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08...
  • Page 34: Reference Materials

    FB-ZC-S MODEL DIMENSIONS Location Inches Millimeters 20-3/8 9-11/16 29-3/4 22-5/7 14-5/8 14-3/4 18-15/16 Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 3-5/8 in. REF 92 mm 3-7/16 in. 87 mm GAS INLET (GAS BALL VALVE NOT SHOWN)
  • Page 35: Vent Kits Components

    FLEX3-30/2: Two 3 inch fl exible liners expands to 30 feet each. FLEX-CNCT: Connector kit - 3 inch liner to 3 inch liner, one connector per kit. Figure 15.3 Direct Vent Flex Liner Accessory Kits Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 FLASH-DAMP LINK-ZC-ADP SVRLINK-ADP FLEX3-30...
  • Page 36: Service Parts

    FB-ZC-S C. Service Parts Beginning Manufacturing Date: Oct. 2007 Service Parts Diagram Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08...
  • Page 37 Pilot Orifi ce LP Regulator NG Regulator LP Additional service parts on following page. COMMENTS Qty 2 Req Qty 2 Req Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 FB-ZC-S Stocked at Depot PART NUMBER LOGS-FBZC SRV2019-701...
  • Page 38 Burner Tube Piezo Ignitor Valve Bracket Valve NG Valve LP Flex Ball Valve Assembly COMMENTS Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 FB-ZC-S Beginning Manufacturing Date: Oct. 2007 Ending Manufacturing Date: ______ Stocked at Depot PART NUMBER...
  • Page 39: Limited Lifetime Warranty

    Page 1 of 2 Wood Pellet Electric Wood Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 Components Covered Venting All Parts and Material Except as covered by Conditions, Exclusion, and Limitations listed...
  • Page 40 If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide necessary parts or components, contact the nearest authorized HHT dealer or supplier. Page 2 of 2 Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 4021-645A 09-01-08...
  • Page 41: Contact Information

    • Read, understand and follow these instructions for safe installation and operation. Printed in U.S.A. - Copyright 2008 Heat & Glo • FB-ZC-S • 2019-910 Rev. G • 11/08 • Leave this manual with party responsible for use and operation.