3-60
MC9000-G Product Reference Guide for Embedded Windows® CE .NET
Reader
Parameters
Laser Values
Reader Type
Laser
Aim Type
Trigger, Timed hold,
Timed Release
Aim Duration 0-60,000 ms
Aim Mode
Dot, Slab, Reticle, None Use only None (no aiming) or Slab (slab aiming).
Beam Width
Normal, Narrow
Raster Mode Smart, Cyclone, None,
Always Open,
Beam Timer
0-60,000 ms
Control LED
False, True
LED Level
High, Low
Class 1 Sup
False, True
Redundancy
None, Bidirectional
Linear Sec
All codes *2
All codes *3
Long*2, Short*3
Short, Redun
Short, Codabar
Pointer Timer 0-60,000 ms
Raster
0-100 in increments of
Height
5 in.
Table 3-8. Laser Scanner Reader Parameters
Laser type scan engine is used.
Trigger mode: On/off controlled by the trigger.
Trigger hold mode: Trigger scan be released but it remains active for the
specified period of time.
Timed release mode: Activation stops after a specified period of time, even if
the trigger is held.
Sets the Aim Duration time duration (0-60,000 ms in increments of 100 ms).
Sets the Beam Width duration to normal or narrow.
Raster Mode, is not supported.
Sets the maximum amount of time that the laser remains on (0-60,000 ms in
increments of 100 ms). A value of 0 sets the laser to stay on.
Control LED is not supported.
LED Level is not supported.
Class 1 Sup is not supported.
Sets the read direction for the barcode redundancy. Bidirectional reads in both
directions.
Sets the number of times a barcode is re-read to confirm an accurate decode.
All codes *2 : Two times read redundancy for all bar codes.
All codes *3 : Three times read redundancy for all bar codes.
Long *2 Short *3: Two times read redundancy for long bar codes, three times
for short bar codes.
Short, Redun: Two times read redundancy based on redundancy flags and
code length.
Short, Codabar: Two times read redundancy if short bar code or CODABAR).
Sets the maximum amount of time that the pointer remains on (0-60,000 ms
in increments of 100 ms). A value of 0 sets the pointer to stay on.
Raster Height is not supported.
Description