If fumes are not being extracted in the best manner possible, we recommend you clean heat exchanger and the extractor as
shown in Figures 22 and 23. However, we recommend that you perform this procedure at least once a year.
11.3 Cleaning the glass
The glass may only be cleaned with the stove completely cold, and using an appropriate product, as per the instructions for
use. You should prevent the product from reaching the sealing ring and painted metal parts so that no undesirable oxidation
occurs. The sealing ring is glued, so should not be exposed to moisture from water or cleaning products.
Figure 25 – Cleaning of the glass: a) moisten a soft cloth with liquid; b) clean the glass with the cloth
Important note (only for the air model): The back of the deflector plate should be cleaned once a year.
Figure 23 – Cleaning the air flow pipes and turbulators
a)
Figure 23 – a) Remove the screws; b) Remove the extractor
Figure 23 – Vacuum the air flow pipes
Figure 24 – Incorrect cleaning of the glass
a)
b)
b)
28