Page 1
FIONN SOLID FUEL BURNING STOVE INSTALLATION AND OPERATING INSTRUCTIONS This appliance is hot while in operation and retains its heat for a long period of time after use. Children, aged or infirm persons should be supervised at all times and should not be allowed to touch the hot working surfaces...
FIONN SOLID FUEL CENTRAL HEATING STOVE INSTALLATION AND OPERATING INSTRUCTIONS Step 7: Install the Hot Plate (16) into the large GENERAL opening of Hob (14). Do not remove the hot plate Before installing your new stove, check that the when the stove is lighting.
CHIMNEY The Fionn Solid Fuel Stove must be connected to a chimney of the correct size and type. The chimney must have a CROSS-SECTIONAL AREA of at least 30.sq. inches (176sq.cm) or a diameter of at least 6” (15.2 cm). It is best to con- 6”...
mostat to the flow pipe of the gravity circuit and Back chimney connection Expansion into existing fireplace or wiring it into the pump control will ensure rapid cir- Pipe solid masonry wall. culation of the hot water. Height to centre of back PIPE THERMOSTAT outlet 530mm (20 Header...
level fire is more effective, particularly in regard to in use.” Operate stove only with fuelling door water heating efficiency. The maximum fuel level is closed. up to the front lip of the coal grate and angled back- wards at approximately 150 LIGHTING It is not unusual for some condensation to form on Lay a few crumbled sheets of paper on the hearth,...
CO ALARM by burial in soil or otherwise locally dispersed , they Waterford Stanley recommend the fitting of a CO should be retained in the closed container until all Alarm in the same room as the appliance, this is a cinders have thoroughly cooled.
FIONN SOLID FUEL STOVE SPECIFICATION Wood Burning Coal Burning Height ................650mm ins. Width.................. 370mm ins. Depth.................. 630mm ins. Flue Size................150mm dia. 6 ins. dia. Height to centre of back of Flue Outlet......530mm Fire Door Size..............264mm W x 280mm H 10 ins.
INSTALLATION CHECK LIST Tick Flue System 1. Minimum Flue Height of 4.6 metres (15 feet). 2. Appliance should be connected to a minimum of 1.8 metres (6 feet) of 150mm (6”) flue pipe with a horizontal run not exceeding 150mm (6”). 3.