9.2
Display information summary
9.2.1
Menu
Menu indicating that the stove power is "off", the room temperature in ºC and Time.
Selecting the operation mode: to select the operation mode, press the "mode" key to
select "Manu" for manual mode or "Auto"
Note: For boiler models manual mode is unavailable.
"Auto" mode: in this mode, the stove shall be turned on at maximum power until reaching a temperature of 1ºC above the
temperature selected (set point temperature). Upon reaching the set temperature, the stove changes to minimum operating
power.
The set-point temperature can be set between 5 and 35ºC by pressing the "-" key.
The "+" key allows the user to set the ventilation speed between 1-5 and automatic mode.
9.2.2
Water temperature
Press the Menu key twice to set the water temperature;
"Water Temp." appears on the display. Press Set to adjust the set point.
· Heating temperature
To set the desired heating temperature press "set". The display starts to flash. Press the "+" or "-" key to select the desired
temperature and then "ok" to confirm.
9.2.3
Date/Time
To set the date and time: press the Menu key twice followed by the "+" . "Day and Time" appears on the display. Press "set" to
see the "Time" menu.
"
MODE
MAN
20.5ºC
16:03
OFF
-
MODE
MAN
Mode:AUTO Menu
Temp:30ºC
Fan:5
-
MODE
MAN
AUT
esc
Set
ESC
<
Data e Hora
>
-
MENU
OFF
OK
+
MENU
OFF
OK
+
MENU
ON
OFF
OK
+
16