4.1

For your safety, we recommend that:

·
Make sure you fully read and understand this instruction manual before using the boiler pellet stove as a biomass heating stove.
·
·
Make sure that the hydronic/ plumbing circuit was correctly assembled and connected to the water supply before turning on the
boiler pellet stove.
·
·
The boiler pellet stove is not intended for use by children or persons with reduced physical, sensory or mental capabilities,
·
·
or lack of experience or knowledge, unless they are under supervision or have been instructed concerning the use of the stove.
·
·
Do not touch the stove when barefoot or if any part of your body is wet or humid;
·
·
Do not tamper with safety or adjustment features without the manufacturer's authorization;
·
·
Do not cover or reduce the size of the vents at the installation area;
·
·
The boiler pellet stove requires a clear space around the stove for proper combustion, so possible air tightness of the location or
any existing air extraction sources in the room may prevent the stove proper operation;
·
The existence of vents is a requisite for proper combustion;
·
·
Do not leave the packing materials near children;
·
·
During normal operation, Free Standing Fire stove's door must not be opened;
·
·
Some parts of the stove may overheat during normal operation, so avoid direct contact with parts such as the door handle and
glass;
·
·
Check the existence of any obstructions on the fume duct before turning on the stove after a long period of inactivity;
·
·
This boiler pellet stove is intended for residential use in protected areas. Safety systems may turn off the stove. If this occurs,
contact the technical assistance. In any circumstances should you attempt to interfere with the safety systems;
·
·
The boiler pellet stove is a biomass heating stove equipped with an electric fume extractor. The occurrence of any power failure
during its use may prevent fume extraction and the room will be filled with smoke. For this reason, you should have a natural
fume extraction system, like a chimney, available;
·
·
During operation, NEVER turn off the free- s t a n d i n g fire stove by disconnecting the electric plug. The fume extractor on
the free-standing pellet fire stove is electric so disconnecting the power plug will prevent the extraction of combustion fumes;
·
·
Your stove must be disconnected from the mains for servicing. Before doing this, the stove must be totally cooled down (if
operating before);
·
·
Never touch the interior of the stove without disconnecting it from the power mains;
·
·
The maximum temperature of the water that can be set by the user (water set-point temperature) is 85°C. In the event of a
temperature of 90ºC being reached, the boiler pellet stove automatically disconnects, and the respective alarm is activated.