9

Use of the Boiler pellet stove

Recommendations
Before starting up the stove, please check the following:
·
Guarantee that the stove is properly connected to the power mains using the 230VAC power cable.
·
Check to see whether the pellet reservoir is supplied with pellets. Inside the pellet reservoir is a safety grid to prevent
users from reaching the worm screw.
·
Ensure that before each lighting the burner is clear
The stove's combustion chamber is made from iron plate and painted with high temperature-resistant paint, releasing
fumes during the first burning sessions due to paint curing.
Make sure that the hydraulic circuit was correctly assembled and is filled to the correct pressure.
You should check that there is sufficient ventilation in the room where the stove is installed, otherwise it will not work properly. You
should therefore check to see whether there are other heating air-consuming stoves in the room (e.g. gas stoves, fire pits,
extractors, etc.); these should not be used simultaneously with the stove.
The Boiler pellet stove stoves have a probe for measuring the room temperature. This probe is attached to the grid on the rear
panel (Figure 20). For a good reading of the room temperature, avoid the contact between the end of the probe and the
stove chassis. You may also attach the probe to the wall beside the stove.
Figure 13 – Electric power plug.
Figure 14 - Room temperature probe
14