Central Strings - Siemens SINUMERIK 840D sl Programming Manual

Measuring cycles
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Data description
9.2 Cycle data
Activate calibration monitoring during "Measuring in automatic mode"
_CBIT[16]=0:
_CBIT[16]=1:
9.2.5

Central strings

Data block GUD6.DEF
_SI[ ]
Central strings (only up to measuring cycle version SW 6.2)
Changes valid after value assignment
Data type STRING
Significance:
_SI[0]
_SI[1]
_SI[2]
Software Version
Here you have to enter the first digit of the version of the NCU software on the control, e.g.
for SW 05.xx.xx, enter 5.
9-26
No calibration monitoring
Calibration monitoring active
The monitoring checks whether the calibration plane, mono/multi probe
calibration or calibration at the probe center point/probe end point between
calibrating and measuring is identical.
Note:
When measuring cycles are called up from "Measuring in JOG" or "ShopMill",
these monitoring checks are always active and cannot be deactivated.
Min. input limit: -
Protection level: -
currently not assigned
Software Version
currently not assigned
Max. input limit: -
Units: -
Applies as of SW
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
Preset default
"6"