Siemens SINUMERIK 840D sl Programming Manual page 65

Measuring cycles
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Auxiliary parameters
Additional parameters can generally be assigned once on a machine. They are then valid for
each additional measuring cycle call until modified by programming or operation.
Parameter
Type
_VMS
REAL
_RF
REAL
_CORA
REAL
_TZL
REAL
_TMV
REAL
_TNVL
REAL
_TUL
REAL
1)
_TLL
REAL
1)
_TDIF
REAL
_TSA
REAL
_FA
REAL
2)
_CM[ ]
REAL
_PRNUM
INT
_EVNUM
INT
_CALNUM
INT
_NMSP
INT
_K
INT
Note
1)
All parameters with dimensions, except for those marked 1), must be programmed in the unit
of measurement of the basic system. The parameters marked 1) must be programmed in the
unit of the active system of units.
2)
_FA is always a value in mm, even when the unit system set is inches.
Measuring cycles
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
Validity
Default
CHAN
0
CHAN
0
CHAN
0
CHAN
0.001
CHAN
0.7
CHAN
1.2
CHAN
1.0
CHAN
-1.0
CHAN
1.2
CHAN
2
CHAN
2
NCK
100, 1000, 1, 0.005,
20, 4, 10, 0
CHAN
1
CHAN
0
CHAN
0
CHAN
1
CHAN
1
Meaning
Variable measuring speed
Feedrate in circular-path programming
Compensation angle, e.g. for mono probe
Zero offset area
Mean value generation with compensation
Limit value for distortion of triangle
Tolerance upper limit
Tolerance lower limit
Dimension difference check
Safe area
Measurement path in mm
Monitoring parameters for tool measurement for a
rotating spindle
Probe number
Number of empirical value memory
Calibration block number
Number of measurements at the same location
Weighting factor for mean value calculation
Parameter description