Siemens SINUMERIK 840D sl Programming Manual page 417

Measuring cycles
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

13200
MEAS_PROBE_LOW_ACTIVE[n]
Switching characteristics of probe (n=0: Measuring input 1, n=1: Measuring input 2)
MD number
When programming MEAS, the data always refers to "not deflected", "deflected" – but not to the
voltage level. The voltage level is set with this MD.
1) up to NCK software version 59.xx.yy
2) as of NCK software version 63.xx.yy
Machine data for adapting MMC commands in cycles
10132
MMC_CMD_TIMEOUT
Monitoring time for MMC command in part program
MD number
Default setting 1
1)
Default setting 3
2)
When using measuring cycles: 3.0
Changes effective after POWER ON
Data type DOUBLE
Significance:
Monitors the time until the MMC acknowledges a command from the part program.
1) up to NCK software version 59.xx.yy
2) as of NCK software version 63.xx.yy
Machine data for logging
11420
LEN_PROTOCOL_FILE
File size for log files
MD number
Default setting: 1
1)
Default setting: 1
2)
When using measuring cycles: 5
Changes effective after POWER ON
Data type DWORD
Significance:
Maximum size of protocol files that are created with WRITE command.
1) up to NCK software version 59.xx.yy
2) as of NCK software version 63.xx.yy
Measuring cycles
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
Min. input limit: 1.0
Protection level: 2/7
Min. input limit: 1
Protection level: 2/7
9.1 Machine data for machine cycle runs
Max. input limit: 100.0
Units: s
Applies as of SW SW 3.2
Max. input limit: 1000000
Units: KB
Applies as of SW SW 4.3
Data description
9-7

Advertisement

Table of Contents
loading

Table of Contents