Miscellaneous functions
7.1 Log measurement results
7.1.7

Log header

Function
The log header can be customized by the operator or a log header prepared by the standard
measuring cycles can be used.
The selection is made via measuring cycle data bit_CBIT[11].
_CBIT[11]=0: Default log header
_CBIT[11]=1: User-defined log header
The contents of the header are stored in an array of string variables _HEADLINE[10], which
are automatically output when logging (CYCLE100) is enabled. The maximum number of
header lines can be changed during measuring cycle start-up (_PROTFORM[3]).
Each field element contains a line for the log header.
User-defined log header
The content of the string array _HEADLINE[ ] is entered in line 1 ff. The number of header
lines can be defined by the user (according to the length of the _HEADLINE).
Default log header
The default log header contains fixed and variable components.
All variable components are in bold formatting, that is:
Line 1 page number,
Line 3 program name,
Line 5, 6, 7 (_HEADLINE[0-2]) ff. and
Line 9 (_PROTVAL[0])
Line 10 (_PROTVAL[1])
Line 1 is fixed and predefined.
Line 1
Line 2
Line 3
Line 4
Line 5
Line 6
Line 7
Line 8
Line 9
Line 10
Line 11
7-8
Date:
98/09/15
Program: MEASPROGRAM_1
Part number: 123456789
Job number: 6878
Supervisor: Müller Phone: 1234
--------------------------------------------------------------------------
---------------
Meas.
, Axis
, Set
point
value
--------------------------------------------------------------------------
--------------
Time:
10:05:30
,
,
, Time
Actual
Differen
value
ce
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0