Power Supply Consumption; Environmental Conditions; Temperature And Humidity; Table 2-20 Power Consumption - NEC Univerge SV8100 System Hardware Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 2.0
6.3
2 - 30
KWh @ AC Input I x 120V/1000: Base chassis = 0.263 KWh,
Expansion chassis = 0.263 KWh, total 1.052 KWh
BTU (KWh) x 3413): Base Chassis = 898BTU,
Expansion Chassis= 898BTU, total 3592 BTU
A dedicated outlet, separately fused and grounded for each chassis
should be installed
6.2.2

Power Supply Consumption

Chassis
Basic Chassis – CD-CP00-US Chassis
Basic Chassis + Expansion Chassis
Basic Chassis + 2 Expansion Chassis
Basic Chassis + 3 Expansion Chassis

Environmental Conditions

6.3.1

Temperature and Humidity

Chassis, Telephones, BCH, BHA, 16LK, Console, ADA, APR
Operating Temperature: +32°F ~ +104°F (0°C ~ 40°C)
Recommended Long Term Temperature: -4°F ~ +140°F
(-20°C ~ 60°C)
Operating Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 90% RH
Blades – PZ-BS10, PZ-BS11, PZ-VM21 Daughter Board, PZ-ME50-US
Daughter Board, CD-8DLCA with PZ-8DLCB Daughter Board,
CD-16DLCA
Operating Temperature: +32°F ~ +104
Recommended Long Term Temperature: -4°F ~ +140°F (-20°C ~ 60°C)
Humidity: 10 ~ 90% RH (non-condensing)
Double Pole/Neutral Fusing
(power supply fuses are located at both the L
and N side).

Table 2-20 Power Consumption

Maximum
RMS
Current
2.19A
4.38A
6.57A
8.76A
UNIVERGE SV8100
Watts Used
Watts Used
(Idle)
(Maximum)
96
192
288
384
o
o
o
F (0
C ~ 40
C)
SV8100 System Specifications
130
260
390
520