Parts Replacement and Clearning > External Auxiliary System > Removing the Upper High Voltage Unit
2) Remove the Feed Driver PCB.
•
6 Screws
•
15 Connectors
x6
4
Parts Replacement and Clearning > External Auxiliary System > Removing the Upper High Voltage Unit
Removing the Upper High Voltage Unit
<Preparation>
1. Remove the Box Cover (Left). (Refer to "Removing the DC Controller PCB")
2. Open the Controller Box. (Refer to "Removing the DC Controller PCB")
<Procedure>
1) Open the Motor Driver PCB Unit.
MEMO:
When opening the Motor Driver PCB Unit, free the top side from the protrusion.
•
5 Connectors
•
Wire Saddle
•
Reuse Band
F-4-502
x5
x2
4-237
Projection
F-4-503
4-237