P821 Spike Filter
Activate the Spike Filter if interference spikes are observed on the long shot Echo
Profile display.
Values:
0 = off
1 = on (preset)
P822 Narrow Echo Filter
Use this feature to remove narrow echoes from profile.
Enter the width of false echoes (in ms), to be removed.
When a value is keyed in, the nearest acceptable value is entered.
Values:
P823 Reform Echo
Enter the amount (in ms) of long shot Echo Profile smoothing required to eliminate
jagged peaks in the Echo Profile.
When a value is keyed in, the nearest acceptable value is entered.
Values:
P825 Echo Marker Percentage
Use this feature when the reported material level fluctuates slightly, due to a
variable rise in the leading or trailing edge of the selected echo on the Echo
Profile.
Enter the value (in percent of echo height) to ensure the Echo Lock Window
intersects the Echo Profile at the steepest slope of the selected echo. This value
becomes the reported level.
Values:
P826 Echo Marker Position
InterRanger DPS300
0 = off (preset), greater = wider
0 = off (preset), greater = wider
5 to 95 (preset: 50)