Oven Door - Amana AO27DG Service Manual

Double gas wall ovens
Hide thumbs Also See for AO27DG:
Table of Contents

Advertisement

Troubleshooting Procedures
!
WARNING
Problem
9.
Broil burner shuts off shortly af-
ter the start of self-clean opera-
tion. Bake and broil functions
operate normally.
10. Oven door cannot be locked.
Solenoid not energizing.
To avoid the risk of electric shock, personal injury or death, disconnect power
To avoid the risk of electric shock, personal injury or death, disconnect power
To avoid the risk of electric shock, personal injury or death, disconnect power
To avoid the risk of electric shock, personal injury or death, disconnect power
To avoid the risk of electric shock, personal injury or death, disconnect power
before servicing, unless testing requires it.
before servicing, unless testing requires it.
before servicing, unless testing requires it.
before servicing, unless testing requires it.
before servicing, unless testing requires it.
Probable Cause
Sail switch contacts not closing.
A.
Selector switch and thermostat
not set in clean position.
B.
Failed momentary latch switch.
C. Failed thermostat contacts.
D. Failed selector switch contacts.
E.
Sail switch contacts not closing.
29
Correction
Check both sail switch contacts
for continuity.
A.
Set selector and thermostat to
clean position.
B.
Move lock lever to center posi-
tion and check for 120 VAC at
the momentary switch terminal
C to neutral. If voltage is
present, check solenoid coil for
continuity. Check for broken
wiring between switch and so-
lenoid and from solenoid to
neutral terminal block. If no volt-
age is present, check switch for
continuity. Check for broken
wiring between latch switch
and thermostat.
C. Check for 120 VAC at thermo-
stat terminal COM to neutral. If
voltage is present, check ther-
mostat contacts for continuity. If
no voltage is present, check for
broken wiring between switch
and thermostat.
D. Check for 120 VAC at selector
switch terminal 3 to neutral. If
voltage is present, check
switch contacts for continuity. If
no voltage is present, check for
broken wiring between selector
switch and sail switches and
between selector switch and
thermal fan switch.
E.
Check sail switch contacts for
continuity. Check for broken
wiring between sail switches
and from hot terminal block to
sail switch. Verify that 120 VAC
is supplied to sail switch.
RA233001 Rev. 3

Hide quick links:

Advertisement

Table of Contents
loading