Installation Instructions
6. Reconnect electrical and gas supplies. Test flame
size and shape. If flame needs further adjustment,
repeat steps one through five.
7. When the flame is properly adjusted, verify air chan-
nel is in place, reassemble the trim and plastic door
knob latch.
Important Note: The air channel must be in place be-
fore operating the oven.
!
WARNING
To avoid the risk of electrical shock and personal
injury, do not attempt to insert anything in the
openings of the protective shield around the ignitor
coil. Do not attempt to clean this area.

Broil Burner Flames

There are two broiler burners, one in the top of each
oven. The broil burners will have a hazy or fuzzy appear-
ance when in operation. This haze may be a maximum
of 3/8-inch thick and is normal for this type of burner.
Important Note: The broil burner flames are not adjust-
able because the burners are equipped with a fixed ori-
fice. The burners do not have air shutters.
Broil Burner Flame

Pressure Regulator Conversion

Several varieties of gas pressure regulators may equip
Amana and Modern Maid gas cooking products. All gas
pressure regulators perform the same function. In most
instances, universal pressure regulators are used in gas
cooking products. A universal regulator can be modified
to use either natural gas or liquefied petroleum (LP) gas
supplies.
Cooking products with universal pressure regulators are
set for a natural gas supply at the factory. Gas cooking
products can be connected to a natural gas supply with-
out modifying the pressure regulator.
A universal pressure regulator, however, must be modi-
fied when connecting a gas cooking product to an LP
gas supply. How each type of universal pressure regula-
tor is converted to LP use is illustrated in the following
examples.
Example One
1. Remove pressure regulator cap with a 7/8-inch
wrench.
2. Remove plastic insert from cap. Insert fits tightly in
cap.
3. Reverse plastic insert. Push firmly into hole in the
cap.
4. Verify insert fits tightly in hole. Do not disturb spring
in regulator body.
5. Replace cap in regulator body.
Example Two
1. Remove cap with screwdriver.
2. Remove insert.
3
Reverse insert and replace. "LPG10" is visible. Do
not disturb spring in regulator body.
4. Replace cap.
Example Three