Common Drive Specifications - YASKAWA GA800 Series Installation & Primary Operation

Ac drive for industrial applications
Hide thumbs Also See for GA800 Series:
Table of Contents

Advertisement

Model
4002
4004
4005
4007
4009
4012
4018
4023
4031
4038
4044
4060
4075
4089
4103
4140
4168
4208
4250
4302
4371
4414
4477
4568
4605
4720
5

Common Drive Specifications

Note:
• To get the OLV, CLV, and AOLV specifications, do Rotational Auto-Tuning.
• To get the longest product life, install the drive in an environment that meets the necessary specifications.
YASKAWA TOEPC71061737B GA800 Drive Installation & Primary Operation
Table 4.3 Output Current for Three-Phase 480 V Models
Heavy Duty Rating (HD)
Parameter C6-01 = 0
Maximum
Rated Output Current
Motor Output
kW (HP)
0.55 (0.75)
1.1 (1.5)
1.5 (2)
2.2 (3)
3.0 (4)
3.7 (5)
5.5 (7.5)
7.5 (10)
11 (15)
15 (20)
18.5 (25)
22 (30)
30 (40)
37 (50)
45 (60)
55 (75)
75 (100)
90 (125)
110 (150)
150 (200)
185 (250)
220 (300)
260 (350)
300 (400)
335 (450)
370 (500)
Maximum
Motor Output
A
kW (HP)
1.8
0.75 (1)
3.4
1.5 (2)
4.8
2.2 (3)
5.5
3 (4)
7.2
3.7 (5)
9.2
5.5 (7.5)
14.8
7.5 (10)
18
11 (15)
24
15 (20)
31
18.5 (25)
39
22 (30)
45
30 (40)
60
37 (50)
75
45 (60)
91
55 (75)
112
75 (100)
150
90 (125)
180
110 (150)
216
150 (200)
260
185 (250)
304
220 (300)
371
260 (350)
414
300 (400)
477
335 (450)
605
370 (500)
605
450 (600)
5 Common Drive Specifications
Normal Duty Rating (ND)
Parameter C6-01 = 1 (Default)
Rated Output Current
A
2.1
4.1
5.4
7.1
8.9
11.9
17.5
23.4
31
38
44
59.6
74.9
89.2
103
140
168
208
250
302
371
414
477
568
675
720
11